Skip to content
-
Features
- Industry-standard Size 20 (50.8mm diameter) stainless steel package
- Flange and servo mounting
- Up to 30,000 PPR
- 80 lb maximum axial and radial shaft loading
- IP67 sealing available
-
Features
- Industry-standard Size 58 (58mm diameter) stainless steel package
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- 100° C operating temperature available
- IP65 sealing available
- Manufactured in Food Grade Stainless Steel
-
Features
- C-Face thru-bore encoder with stainless steel housing
- Fits NEMA Size 56C thru 184C motor faces (4.5" AK)
- Slim profile—only 25.4mm deep
- Incorporates Opto-ASIC technology
- Resolutions to 4096 PPR
-
Features
- Standard Size 25 package (2.5")
- Resolutions up to 12-bit (4096 counts)
- Incorporates Opto-ASIC technology
- Industrial-grade, heavy-duty housing
- Optional IP67 seal
-
Features
- Low profile—40mm
- Thru-bore or hollow-bore styles
- Industrial-grade, heavy-duty housing
- State-of-the-art Opto-ASIC circuitry
-
Features
- Standard Size 36mm package (1.42")
- Durable magnetic technology
- Multiturn absolute encoder (12-bit/39-bit)
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Standard Size 36mm package (1.42")
- Durable magnetic technology
- Multiturn absolute encoder (12-bit/39-bit)
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Multi-Turn Absolute Encoder (14 Bit/39 Bit)
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Proven Turns Counting Technology – No Gears or Batteries
- Retains Absolute Position After a Power Outage
-
Features
- Standard Size 36mm package
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven turns counting technology—no gears or batteries
- Flex mount eliminates couplings and is ideal for motors or shafts
-
Features
- Standard size 36 mm package (1.42")
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Up to 14 Bits of Single-Turn Resolution
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Retains Absolute Position After a Power Outage
-
Features
- Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
- Stainless steel shaft and ball bearing - ball bearing with Simmer ring
- Rotor with shaft and permanent magnet mounted in pre-chamber
- Sensor circuit consisting of ASIC
- Hall elements and interface electronics in enclosed main chamber
- Housing protection type IP 69K additionally cast
- Electrical connection via cable (open cable ends)
-
Features
- Interface: SSI
- Design: 42mm
- Housing Material: Aluminium, stainless steel
- Flange & Shaft: Synchroniser flange
- Resolution: 4096 steps/360°<)
- Code type: Binary, Gray (optional)
- Electrical connection: Cable 1m
- Electrical and/or mechanical variant: Basic version
-
Features
- Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
- Stainless steel shaft and ball bearing - ball bearing with Simmer ring
- Rotor with shaft and permanent magnet mounted in pre-chamber
- Sensor circuit consisting of ASIC
- Hall elements and interface electronics in enclosed main chamber
- Housing protection type IP 69K additionally cast
- Electrical connection via cable (open cable ends)
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
- 8-decade LCD display (colour: red, green, yellow)
- Resistive touchscreen
- Standard housing with 96 x 48 mm and IP65 protection
- Intuitive and easy parameterization by plain text and touchscreen
- Numerous functions such as scaling, filter, zero offset, counting direction etc.
- Linearization with 24 interpolation points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
- 4 control inputs for HTL, PNP signals [10 ... 30 VDC]
- Input and output frequency up to 1 MHz
- 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
- Power supply 9 ... 30 VDC
- Snap-on housing for top-hat rail (acc. EN 60715)
- Multiplier/divisor adjustable as quotient F1 / F2
- Multiplication/division without cumulative residual errors
- Additional functions such as jog, trim, offset and reference
Page load link