• Features

    • Standard 68mm Diameter Package
    • Up to 30000 PPR, Opto-Asic Technology
    • Square Flange Mounting
    • IP65 Double O-ring Sealed
  • Features

    • Transverse Slotted Shaft
    • Up to 30000 PPR, Opto-Asic Technology
    • 90mm Round Flange with 3 x 4.5mm Dia Fixing Holes at 120° Apart on a 82mm PCD
    • Double O-ring Sealed
  • Features

    • Body: Precision Machined Aluminium
    • Cover: Precision Machined Aluminium (Powder Coated)
    • Shaft: Stainless Steel
    • Bearings: Ballraces
    • Shaft Sealing: Front: Sealed bearing
    • Rear: Single lip seal on the rear of the cover
    • Protection: IP65
    • Operating Temp: -20 to +60°C (Higher on request)
    • Maximum Speed: 3000 RPM (Higher on request)
    • Torque: 3Ncm (typical)
    • Inertia: 600gcm2 (typical)
    • Shaft Loading: Designed to support its weight
    • Cable: Screened, oil and salt waterproof
    • Impulse Frequency: Up to 300KHz (depending on model)
    • Current Consumption: 60mA (typical – without load)
  • Features

    • Standard Size 25 package (2.5")
    • Resolutions up to 12-bit (4096 counts)
    • Incorporates Opto-ASIC technology
    • Industrial-grade, heavy-duty housing
    • Optional IP67 seal
  • Features

    • Low profile—40mm
    • Thru-bore or hollow-bore styles
    • Industrial-grade, heavy-duty housing
    • State-of-the-art Opto-ASIC circuitry
  • Features

    • Number of output pulses per revolution 5.000 - 500.000 ppr
    • Line number on disc (z) 5.000
    • Maximum shaft speed 8000 rpm
    • The permissible motion of the shaft - axial: ± 1.00 mm - radial: 0.02 mm
    • Accuracy (T1-period lines on disc in arc. sec) ± 0.05T1 arc. sec
    • Starting torque at 20°C ≤ 0.01 Nm
    • Rotor moment of inertia < 20x10-4 kgm2
    • Protection (housing) (IEC 529) IP64
    • Protection (shaft side) (IEC 529) IP64
    • Maximum weight without cable 0.8 kg
    • Operating temperature -20...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000
    • Reference signal - standard: 1 per shaft revolution - distance coded: 36 per shaft revolution
    • Maximum shaft speed 5000 rpm
    • Maximum shaft load - radial: 10 N
    • Accuracy ± 7.5 arc. sec; ± 5.0 arc. sec
    • Starting torque at 20°C ≤ 0.01 Nm
    • Rotor moment of inertia < 20x10-6 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 0.7 kg
    • Operating temperature 0...+50°C
    • Storage temperature -30...+80°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000; 36000
    • Reference signal - standard: 1 per shaft revolution - distance coded for z = 18000: 36 per shaft revolution - distance coded for z = 36000: 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.5 arc. sec
    • Permissible shaft load - axial: ≤ 30 N - radial: ≤ 30 N
    • Starting torque at 20°C ≤ 0.012 Nm
    • Rotor moment of inertia < 3.7x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 3.5 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000; 36000
    • Reference signal - standard: 1 per shaft revolution - distance coded for z = 18000: 36 per shaft revolution - distance coded for z = 36000: 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.5 arc. sec
    • Permissible shaft load - axial: 0.02 mm - radial: 0.02 mm
    • Starting torque at 20°C ≤ 0.012 Nm
    • Rotor moment of inertia < 3.7x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 4.1 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 3.600.000
    • Line number on disc (z) 36000
    • Reference signal - 1 per shaft revolution - 36 per shaft revolution - 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.0 arc. sec
    • Permissible shaft load - axial: 0.02 mm - radial: 0.02 mm
    • Starting torque at 20°C ≤ 0.5 Nm
    • Rotor moment of inertia < 0.9x10-3 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 4.5 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Type: Photoelectric rotary encoder (converts rotational movement into electrical signals)
    • Function: Incremental (tracks changes in rotation rather than absolute position)
    • Diameter: Compact size of 28 mm
    • High resolution: Up to 25,000 output pulses per revolution (providing detailed rotational information)
    • Benefit: Well-suited for applications with limited space due to its small size
  • Features

    • Number of output pulses per revolution 100-108000 ppr
    • Maximum shaft speed 10000 rpm
    • The permissible motion of the shaft - axial: ± 0.5 mm - radial: ± 0.05 mm
    • Accuracy (T1-period lines on disc in arc. sec) ± 0.1T1 arc. sec
    • Starting torque at 20°C ≤ 0.025 Nm
    • Rotor moment of inertia < 1.5x10-4 kgm2
    • Protection (housing) (IEC 529) IP64
    • Protection (shaft side) (IEC 529) IP64
    • Maximum weight without cable 0.3 kg
    • Operating temperature -10...+70°C
    • Storage temperature -30...+80°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (5 ms) ≤ 1000 m/s²
  • Features

    • Miniature size (38.1mm diameter)
    • Up to 30,000 PPR
    • Servo or flange mounting
    • 1 MHz frequency response available
    • Extended temperature operating range available
  • Features

    • Standard Size 58 mounting (58 mm diameter)
    • Up to 30,000 PPR
    • 36 Kg max. Axial and radial shaft loading
    • High-temperature option (100° C)
    • IP65 sealing available
  • Features

    • Standard Size 58 mounting (58 mm diameter)
    • Up to 30,000 PPR
    • 36 Kg max. Axial and radial shaft loading
    • High temperature option (100° C)
    • IP65 sealing available
  • Features

    • Standard Size 36mm package (1.42")
    • Durable magnetic technology
    • Multiturn absolute encoder (12-bit/39-bit)
    • SSI and CANopen communications
    • Proven new turns counting technology — no gears or batteries
  • Features

    • Standard Size 36mm package (1.42")
    • Durable magnetic technology
    • Multiturn absolute encoder (12-bit/39-bit)
    • SSI and CANopen communications
    • Proven new turns counting technology — no gears or batteries
  • Features

    • Multi-Turn Absolute Encoder (14 Bit/39 Bit)
    • SSI and CANopen Communications
    • 58 mm Diameter
    • Durable Magnetic Technology
    • Proven Turns Counting Technology – No Gears or Batteries
    • Retains Absolute Position After a Power Outage
  • Features

    • Standard Size 36mm package
    • Durable magnetic technology
    • Up to 14 bits of single-turn resolution
    • SSI and CANopen communications
    • Proven turns counting technology—no gears or batteries
    • Flex mount eliminates couplings and is ideal for motors or shafts
  • Features

    • Standard size 36 mm package (1.42")
    • Durable magnetic technology
    • Up to 14 bits of single-turn resolution
    • SSI and CANopen communications
    • Proven new turns counting technology — no gears or batteries
  • Features

    • Up to 14 Bits of Single-Turn Resolution
    • SSI and CANopen Communications
    • 58 mm Diameter
    • Durable Magnetic Technology
    • Retains Absolute Position After a Power Outage
  • Features

    • Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
    • Stainless steel shaft and ball bearing - ball bearing with Simmer ring
    • Rotor with shaft and permanent magnet mounted in pre-chamber
    • Sensor circuit consisting of ASIC
    • Hall elements and interface electronics in enclosed main chamber
    • Housing protection type IP 69K additionally cast
    • Electrical connection via cable (open cable ends)
  • Features

    • Interface: SSI
    • Design: 42mm
    • Housing Material: Aluminium, stainless steel
    • Flange & Shaft: Synchroniser flange
    • Resolution: 4096 steps/360°<)
    • Code type: Binary, Gray (optional)
    • Electrical connection: Cable 1m
    • Electrical and/or mechanical variant: Basic version
  • Features

    • Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
    • Stainless steel shaft and ball bearing - ball bearing with Simmer ring
    • Rotor with shaft and permanent magnet mounted in pre-chamber
    • Sensor circuit consisting of ASIC
    • Hall elements and interface electronics in enclosed main chamber
    • Housing protection type IP 69K additionally cast
    • Electrical connection via cable (open cable ends)
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000
    • Reference signal - standard: 1 per shaft revolution - distance coded: 36 per shaft revolution
    • Permissible mech. speed ≤ 3000 rpm
    • Max. operating speed 600 to 1000 rpm
    • Accuracy grades ± 5.0 arc. sec
    • Permissible shaft runout - axial: 0.02 mm - radial: ± 0.02 mm
    • Starting torque at 20°C ≤ 0.08 Nm
    • Rotor moment of inertia < 0.6x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 1.2 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²