• Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3/PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • Sub-D-9 connectors (male) on both sides
    • cable length 10 cm (approx. 3.4")
  • Features

    • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 1 Strain gauge input
    • 3 VDC and 10 VDC bridge voltage per sensor connection
    • 1 … 10 mV sensitivity
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
    • 9600 Bit/s ... 12 MBit/s Baud rates
    • SUB-D-9-pin female, galvanically isolated
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
    • 100 MBit/s Vollduplex
    • 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
  • Features

    • 1 connector Sub-D-9 (male)
    • 1 connector Sub-D-9 (female)
    • cable length 3 m (approx. 10 feet)
     
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • USB cable for connection between PC and the Motrona unit UZ210
    • Both connectors are type A
    • Cable length 2 m (approx. 6.5 feet)
  • Features

    • USB cable for connection between PC operator software and Motrona DS device
    • USB connector type A on type B
    • Length 1,8 m
  • Features

    • USB cable for connection between PC and Motrona devices of the series IV/FU/PV/ZU210 and IP/FP/PP/ZP210
    • USB connector type A on type Mini B
    • Length 1,8 m
  • Features

    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Ultra Miniature Size
    • High reliability with mounting the Opt-ASIC (by components quantities decreased)
    • Low torque and low inertia
    • High signal accuracy
    • Type: 12SA
    • Pulse: 100-256
    • Outer Diameter: φ12
    • Ingress Protection: IP00
  • Features

    • Ultra Miniature Size
    • Shaft Diameter of 2.5mm available
    • Type: 18M
    • Pulse: 200-1600
    • Outer Diameter: φ18