Skip to content
-
Features
- Standard Size 36mm package (1.42")
- Durable magnetic technology
- Multiturn absolute encoder (12-bit/39-bit)
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Multi-Turn Absolute Encoder (14 Bit/39 Bit)
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Proven Turns Counting Technology – No Gears or Batteries
- Retains Absolute Position After a Power Outage
-
Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 nsec.
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW217)
- Power supply 10 ... 30 VDC (for LW217-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW218)
- Power supply 10 ... 30 VDC (for LW218-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Glass fibre cables are available ready-assembled
-
Features
- 1 connector Sub-D-9 (male)
- 1 connector Sub-D-9 (female)
- cable length 3 m (approx. 10 feet)
-
Features
- Support brackets with a snap mechanism for easy installation of panel housings onto a 35 mm DIN rail (according to EN 60715)
- Suitable for display units with front dimensions of 96 x 48 mm
-
Features
- Support brackets with a snap mechanism for easy installation of panel housings onto a 35 mm DIN rail (according to EN 60715)
- Suitable for display units with front dimensions of 96 x 96 mm
-
Features
- USB cable for connection between PC and the Motrona unit UZ210
- Both connectors are type A
- Cable length 2 m (approx. 6.5 feet)
-
Features
- Hollow Shaft Small Size
- Resolution (Counts/Turn): 1,000∼12,000C/T
- Output Phase: A, B, Z, EU, EV, EW Phase
- Max Response Frequency: 200kHz
- Supply Voltage: DC+5V
- Consumption Current: 200mA Max
- Output Form: Line Driver
- Mounting Tolerance: Radial 0.05mm TIR Max, Axial 0.2mm Max, Shaft Runout 0.1°Max
- Starting Torque: 9.8×10-3N⋅m (100gf⋅cm Max)
- Protection: IP=40
- Operating Temp. Range: -20∼+85°C
- Vibration: 49m/s2(5G)
- Shock: 980m/s2(100G)
- Mass: 0.3kg Max
-
Features
- Hollow Shaft Small Size
- Resolution (Counts/Turn): 1,000∼12,000C/T
- Output Phase: A, B, Z, EU, EV, EW Phase
- Max Response Frequency: 200kHz
- Supply Voltage: DC+5V
- Consumption Current: 200mA Max
- Output Form: Line Driver
- Mounting Tolerance: Radial 0.05mm TIR Max, Axial 0.2mm Max, Shaft Runout 0.1°Max
- Starting Torque: 9.8×10-3N⋅m (100gf⋅cm Max)
- Protection: IP=40
- Operating Temp. Range: -20∼+85°C
- Vibration: 49m/s2(5G)
- Shock: 980m/s2(100G)
- Mass: 0.3kg Max
-
Features
- Hollow Shaft Small Size
- Resolution (Counts/Turn): 1,000∼12,000C/T
- Output Phase: A, B, Z, EU, EV, EW Phase
- Max Response Frequency: 200kHz
- Supply Voltage: DC+5V
- Consumption Current: 200mA Max
- Output Form: Line Driver
- Mounting Tolerance: Radial 0.05mm TIR Max, Axial 0.2mm Max, Shaft Runout 0.1°Max
- Starting Torque: 9.8×10-3N⋅m (100gf⋅cm Max)
- Protection: IP=40
- Operating Temp. Range: -20∼+85°C
- Vibration: 49m/s2(5G)
- Shock: 980m/s2(100G)
- Mass: 0.3kg Max
Page load link