Skip to content
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
2 Incremental inputs with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
Power supply 18 ... 30 VDC
5 / 24 VDC auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, process time, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
EtherCAT interface
3 control inputs for remote release
Power supply 18 ... 30 VDC
Norm panel housing with 96 x 48 mm and protection class IP65
Bright and high-contrast graphic display with event-dependent color variants
Emulation of a 7-segment display with symbols, units and bargraph
Intuitive and simple parameterization through plain text and touchscreen
Features
EtherNET/IP interface
3 control inputs for remote release
Power supply 18 ... 30 VDC
Norm panel housing with 96 x 48 mm and protection class IP65
Bright and high-contrast graphic display with event-dependent color variants
Emulation of a 7-segment display with symbols, units and bargraph
Intuitive and simple parameterization through plain text and touchscreen
Features
Sub-D-9 connectors (male) on both sides
cable length 10 cm (approx. 3.4")
Features
Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
4 control inputs for HTL, PNP signals [10 ... 30 VDC]
Input and output frequency up to 1 MHz
3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
Power supply 9 ... 30 VDC
Snap-on housing for top-hat rail (acc. EN 60715)
Multiplier/divisor adjustable as quotient F1 / F2
Multiplication/division without cumulative residual errors
Additional functions such as jog, trim, offset and reference
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
4 control inputs for PNP signals [10 ... 30 VDC]
Input and output frequency up to 1 MHz
Pulse output with format A, /A, B, /B, Z, /Z and
push-pull characteristic, [5 ... 30 VDC]
Power supply 11 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
LCD backlighted
Setup via keys, RS232
The device multiplies an incoming frequency by a proportional factor F1 and a reciprocal factor F2. The two factors F1 and F2 are adjustable in the range of 0.0005 to 9.9999
All operation modes provide error-free frequency conversion, with full consideration of the A / B phase and direction of the quadrature signals, therefore no cumulative errors, even with continuous changes of directions and vibrations
Zero pulse generator: the frequency multiplier generates at the output an index signal with an adjustable pulse interval, which can be synchronized as needed with the zero pulse at the input
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse input in format A, B, Z [HTL]
Input frequency up to 1 MHz
Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse output in format A, B, Z [HTL]
Power supply 9 ... 30 VDC
Settings via DIL switches
Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
External HTL signals for various functions
Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
Snap-on housing for top-hat rail (acc. EN 60715)
Dimension (B x H X T) 22,5 x 102 x 102 mm
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
High level of internal safety (detection of internal errors and failures of the device components)
2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
6 logical inputs for PNP signals [10 ... 30 VDC]
Input frequency up to 500 kHz
4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
4 forced-guided redundant output relays with potential free change-over contact
Serial interface RS232 and RS485
Power supply 24 VAC and 17 ... 40 VDC
Compact norm panel housing
6 digits LED display with 15 mm height
Display range -199999 ... 999999
Setup by keys or PC via serial RS232 Interface
Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
9600 Bit/s ... 12 MBit/s Baud rates
SUB-D-9-pin female, galvanically isolated
Features
Profinet interface
3 control inputs for remote release
Power supply 18 ... 30 VDC
Norm panel housing with 96 x 48 mm and protection class IP65
Bright and high-contrast graphic display with event-dependent color variants
Emulation of a 7-segment display with symbols and units
Intuitive and simple parameterization through plain text and touchscreen
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
100 MBit/s Vollduplex
2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
Power supply 18 ... 30 VDC
Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
Simple parameterization via the OS6.0 user interface
Serial RS232 / RS485 interface
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
USB interface and RS232/RS485 interface for configuration and serial readout
Features
1 connector Sub-D-9 (male)
1 connector Sub-D-9 (female)
cable length 3 m (approx. 10 feet)
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
USB cable for connection between PC and the Motrona unit UZ210
Both connectors are type A
Cable length 2 m (approx. 6.5 feet)
Features
USB cable for connection between PC operator software and Motrona DS device
USB connector type A on type B
Length 1,8 m
Features
USB cable for connection between PC and Motrona devices of the series IV/FU/PV/ZU210 and IP/FP/PP/ZP210
USB connector type A on type Mini B
Length 1,8 m
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
4 preselector switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Page load link