Skip to content
Features
Standard Size 36mm package (1.42")
Durable magnetic technology
Multiturn absolute encoder (12-bit/39-bit)
SSI and CANopen communications
Proven new turns counting technology — no gears or batteries
Features
Multi-Turn Absolute Encoder (14 Bit/39 Bit)
SSI and CANopen Communications
58 mm Diameter
Durable Magnetic Technology
Proven Turns Counting Technology – No Gears or Batteries
Retains Absolute Position After a Power Outage
Features
Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
Power supply 24 VDC
Miniature norm panel housing
5 digits LED display with 8 mm height
Display range -19999 ... 99999, adjustable zero and full-scale value
Latch input to freeze the display, minimum/maximum record memory
Easy to set up with only two front keys and menu support
Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
Features
2 universal 16-bit analog inputs for ±10 V or 0/4 … 20 mA
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
High accuracy reference output 10 V for potentiometers > 1 kOhm
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
Numerous features, e. g. Ttara, filters, averaging
Linearization with 24 control points
Option IO (= IO-Link Device)
Data transfer via COM3 (230,4 kBaud)
Cycle times < 3 msec
Process data IN 32 Byte (6 x process values from AX350):
- Analog value 1 (scaled / linearized) and unit
- Analog value 2 (scaled / linearized) and unit
- Analog value 1 (scaled / linearized) with totalisation and unit
- Analog value 2 (scaled / linearized) with totalisation and unit
- Shortcut analogue value 1 (scaled / linearized) with analogue value 2 (scaled / linearized) and unit
- Shortcut totalisator analogue value 1 (scaled / linearized) with totalisator analogue value 2 (scaled / linearized) and unit
Process data Out 8 Byte (2 x IO-Link process values to AX350):
- IOL process value Out 1 with scaling, adjustable decimal point and programmable units
- IOL process values Out 2 with scaling, adjustable decimal point and programmable units
Combinable with further options:
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
SUB-D-9-pin male, galvanically isolated
Features
USB to RS232 converter (compatible with all existing Windows versions)
Serial RS232 cable (for connection between the converter and motrona unit)
One connector Sub-D-9 (male)
One connector Sub-D-9 (female)
Length 3 m (approx. 10 feet)
Windows driver CD enclosed
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
8-decade LCD display (colour: red, green, yellow)
Resistive touchscreen
Standard housing with 96 x 48 mm and IP65 protection
Intuitive and easy parameterization by plain text and touchscreen
Numerous functions such as scaling, filter, zero offset, counting direction etc.
Linearization with 24 interpolation points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 500 kHz
2 output relays with potential-free change-over contact (forward, reward and zero motion)
2 transistor outputs with High-Side-Driver, short-circuit-proof
Power supply 17 ... 30 VDC
Snap-on housing for top hat rail (according to EN 60715)
DIL switch for setup of input characteristic and definition of standstill
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
14 Bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 fast transistor switching outputs [PNP]
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Sub-D-9 connectors (male) on both sides
cable length 10 cm (approx. 3.4")
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling and bit blanking
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
5 / 24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling, bit blanking and wire break monitoring
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
9600 Bit/s ... 12 MBit/s Baud rates
SUB-D-9-pin female, galvanically isolated
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
100 MBit/s Vollduplex
2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Page load link