Skip to content
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
Sub-D-9 connectors (male) on both sides
cable length 10 cm (approx. 3.4")
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distances up to 3000 meters
Power supply 5 VDC (for LW214)
Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW215)
Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW216)
Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 Error input (LW217) resp. 1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 nsec.
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW217)
Power supply 10 ... 30 VDC (for LW217-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW218)
Power supply 10 ... 30 VDC (for LW218-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Glass fibre cables are available ready-assembled
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
9600 Bit/s ... 12 MBit/s Baud rates
SUB-D-9-pin female, galvanically isolated
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
100 MBit/s Vollduplex
2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
Features
2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 300 kHz
4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
Loop time approx. 250 µs
Defining incremental dimensions via keyboard
Power supply 24 VAC and 17 … 40 VDC
Compact norm panel housing (according to EN 60715)
Top hat rail mounting by using SM300 support brackets (option)
Setup via keys or via PC by serial RS232 interface
PROFIBUS connection via mMotrona gateway PB251
Features
2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 300 kHz
4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
Loop time approx. 250 µs
Defining incremental dimensions via keyboard or BCD decade switch on the front
Power supply 24 VAC and 17 … 40 VDC
Compact norm panel housing (according to EN 60715)
Top hat rail mounting by using SM600 support brackets (option)
Setup via keys or via PC by serial RS232 interface
PROFIBUS connection via Motrona gateway PB251
Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")
Features
1 connector Sub-D-9 (male)
1 connector Sub-D-9 (female)
cable length 3 m (approx. 10 feet)
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
USB cable for connection between PC and the Motrona unit UZ210
Both connectors are type A
Cable length 2 m (approx. 6.5 feet)
Features
USB cable for connection between PC operator software and Motrona DS device
USB connector type A on type B
Length 1,8 m
Features
USB cable for connection between PC and Motrona devices of the series IV/FU/PV/ZU210 and IP/FP/PP/ZP210
USB connector type A on type Mini B
Length 1,8 m
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC
Page load link