Skip to content
-
Features
- Standard Size 36mm package (1.42")
- Durable magnetic technology
- Multiturn absolute encoder (12-bit/39-bit)
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
- 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
- SUB-D-9-pin male, galvanically isolated
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 1 SSI input (10 … 32 bit)
- for single-turn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
- Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- SSI clock frequency up to 1 MHz
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling and bit blanking
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 5 / 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling, bit blanking and wire break monitoring
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
- High level of internal safety (detection of internal errors and failures of the device components)
- 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- 6 logical inputs for PNP signals [10 ... 30 VDC]
- Input frequency up to 500 kHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 forced-guided redundant output relays with potential free change-over contact
- Serial interface RS232 and RS485
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- Setup by keys or PC via serial RS232 Interface
- Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Incremental input with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
- 9600 Bit/s ... 12 MBit/s Baud rates
- SUB-D-9-pin female, galvanically isolated
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
- 100 MBit/s Vollduplex
- 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
-
Features
- 20-bit parallel input with format BCD, binary or Gray-Code
- Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
- 4 status outputs, with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Power supply 10 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Serial RS232 / RS485 interface
-
Features
- 1 connector Sub-D-9 (male)
- 1 connector Sub-D-9 (female)
- cable length 3 m (approx. 10 feet)
-
Features
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Power supply 17 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)