Skip to content
-
Features
- 5mm Opto-ASIC encoder with a low profile (50.8mm)
- Imperial bore sizes range from 0.625” to 1.125”
- Metric bore sizes ranging from 6 mm to 28 mm
- Single replacement solution for 50.8mm to 88.9mm encoders
- Resolutions to 10,000 PPR, frequencies to 1 MHz
- Versatile flexible mounting options
- RoHS compliant
- Corrosion-Resistant Option
-
Features
- 58 mm package available in thru-bore or hollow bore
- Resolutions from 1 to 65,536 PPR
- 6 different output types to choose from
- 32 different waveforms available
- Standard and Metric Bore Sizes up to 5/8” and 15 mm
- Several Flexible Mounting Options
- IP67 Sealing Available
-
Features
- Miniature size (38.1mm diameter)
- Up to 30,000 PPR
- Flex mounting & large hollow bore option (Up to 14mm)
- High-temperature option
-
Features
- Size 25 / 63.5mm Diameter (Hollow Shaft)
- Up to 12 Pole Commutation Available
- Thru Bore and Blind Bore Options
- Simple, Innovative Flexible Mounting System
- Incorporates Opto-ASIC Technology
-
Features
- Number of output pulses per revolution 100-108000 ppr
- Maximum shaft speed 10000 rpm
- Permissible motion of shaft - axial: ± 0.5 mm- radial: ± 0.05 mm
- Accuracy (T1-period lines on disc in arc. sec) ± 0.1T1 arc. sec
- Starting torque at 20°C ≤ 0.025 Nm
- Rotor moment of inertia < 1.5x10-4 kgm2
- Protection (housing) (IEC 529) IP64
- Protection (shaft side) (IEC 529) IP64
- Maximum weight without cable 0.3 kg
- Operating temperature -10...+70°C
- Storage temperature -30...+80°C
- Maximum humidity (non-condensing) 98%
- Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
- Permissible shock (5 ms) ≤ 1000 m/s²
-
Features
- Standard Size 36mm package (1.42")
- Durable magnetic technology
- Multiturn absolute encoder (12-bit/39-bit)
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 1 Strain gauge input
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 1 SSI input (10 … 32 bit)
- for single-turn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
- Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- SSI clock frequency up to 1 MHz
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling and bit blanking
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 5 / 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling, bit blanking and wire break monitoring
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Incremental input with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- 20-bit parallel input with format BCD, binary or Gray-Code
- Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
- 4 status outputs, with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Power supply 10 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Serial RS232 / RS485 interface
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via mMotrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard or BCD decade switch on the front
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
- Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")
Page load link