Standard Size 36mm package (1.42")
Durable magnetic technology
Multiturn absolute encoder (12-bit/39-bit)
SSI and CANopen communications
Proven new turns counting technology — no gears or batteries
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
2 x 6 control outputs für HTL / PNP signals
Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 1 MHz
2 encoder outputs, short-circuit-proof [TTL / RS422]
Power supply 12 ... 30 VDC
Current consumption (unloaded) 30 mA
Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
Operation temperature: 0 ... 60 °C (32 ... 140°F)
Latency time < 250ns
Channel switching < 1 ms
Open plastic housing for top-hat rail (according to EN 60715)
LEDs for indication of the input pulses
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
Input frequency 750 kHz [TTL] or 300 kHz [HTL]
2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
Power supply optionally 5 VDC or 10 ... 30 VDC
Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
Features
2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
2 control inputs for HTL / PNP signals [10 ... 30 VDC]
2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Control input „Error Release“ for PNP signals [10 ... 30 VDC]
Input frequency up to 400 kHz
Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
Output frequency up to 4 MHz [RS422]
Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Adjustable multiplier for interpolation rates from 1:5 to 1:50
Adjustable divider 1:1 – 1:255 to reduce the output frequency
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
Suitable for display units with front dimensions 96 x 48 mm
(fits not to Profibus indicator PB340)
Protection class IP65
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC