Skip to content
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
4 pulse inputs with format A, /A, B, /B [RS422]
4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
8 control inputs for PNP signals [10 ... 30 VDC]
4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
Short loop time (depending on application)
Power supply 18 ... 35 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via Windows operator software (free of charge)
OnBoard interfaces: RS232 and CANopen
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
Suitable for display units with front dimensions 96 x 48 mm
(fits not to Profibus indicator PB340)
Protection class IP65
Features
To increase the protection class in dusty or wet environments, several types of protection caps are available for motrona units.
Some of the elastic and transparent plastic caps allow you to operate the keypad or to set the thumbwheel switches behind the cap, without removing it.