• Features

    • 1 incremental input (A, /A, B, /B)
    • for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 1 SSI input (10 … 32 bit)
    • for single-turn and multiturn encoders
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • SSI input  with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
    • Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • SSI clock frequency up to 1 MHz
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • Scalable 14 bit analog input  for ±10 V or 0/4 ... 20 mA
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Pulse output with format  A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • SSI output with format  DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Various user modes: Programmable V / f characteristics,  programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
    • USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
    • Adjustable filter functions as well as operator programmable linearization curves
    • Printer mode for automatic data transfer of internal registers to a data logger or PC
Go to Top