• Features

    • Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse input in format A, B, Z [HTL]
    • Input frequency up to 1 MHz
    • Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse output in format A, B, Z [HTL]
    • Power supply 9 ... 30 VDC
    • Settings via DIL switches
    • Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
    • Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
    • Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
    • External HTL signals for various functions
    • Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Dimension (B x H X T) 22,5 x 102 x 102 mm
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen
  • Features

    • Suitable for display units with front dimensions 96 x 48 mm (fits not to Profibus indicator PB340)
    • Protection class IP65
  • Features

    • Scalable 14 bit analog input  for ±10 V or 0/4 ... 20 mA
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Pulse output with format  A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • SSI output with format  DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Various user modes: Programmable V / f characteristics,  programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
    • USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
    • Adjustable filter functions as well as operator programmable linearization curves
    • Printer mode for automatic data transfer of internal registers to a data logger or PC
  • Features

    • To increase the protection class in dusty or wet environments, several types of protection caps are available for motrona units.
    • Some of the elastic and transparent plastic caps allow you to operate the keypad or to set the thumbwheel switches behind the cap, without removing it.