Skip to content
-
Features
- Industry-standard Size 20 (50.8mm diameter) stainless steel package
- Flange and servo mounting
- Up to 30,000 PPR
- 80 lb maximum axial and radial shaft loading
- IP67 sealing available
-
Features
- Industry-standard Size 58 (58mm diameter) stainless steel package
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- 100° C operating temperature available
- IP65 sealing available
- Manufactured in Food Grade Stainless Steel
-
Features
- C-Face thru-bore encoder with stainless steel housing
- Fits NEMA Size 56C thru 184C motor faces (4.5" AK)
- Slim profile—only 25.4mm deep
- Incorporates Opto-ASIC technology
- Resolutions to 4096 PPR
-
Features
- Low profile—40mm
- Thru-bore or hollow-bore styles
- Industrial-grade, heavy-duty housing
- State-of-the-art Opto-ASIC circuitry
-
Features
- Standard Size 36mm package
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven turns counting technology—no gears or batteries
- Flex mount eliminates couplings and is ideal for motors or shafts
-
Features
- Up to 14 Bits of Single-Turn Resolution
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Retains Absolute Position After a Power Outage
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Cutting length specification via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 4 potential-free changeover relay outputs
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Cutting length specification via BCD decade switch on the front
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 500 kHz
- 2 output relays with potential-free change-over contact (forward, reward and zero motion)
- 2 transistor outputs with High-Side-Driver, short-circuit-proof
- Power supply 17 ... 30 VDC
- Snap-on housing for top hat rail (according to EN 60715)
- DIL switch for setup of input characteristic and definition of standstill
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- 14 Bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 fast transistor switching outputs [PNP]
- 14 bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 14 bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 2 x 6 control outputs für HTL / PNP signals
- Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 1 MHz
- 2 encoder outputs, short-circuit-proof [TTL / RS422]
- Power supply 12 ... 30 VDC
- Current consumption (unloaded) 30 mA
- Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
- Operation temperature: 0 ... 60 °C (32 ... 140°F)
- Latency time < 250ns
- Channel switching < 1 ms
- Open plastic housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Page load link