Skip to content
-
Features
- Low profile—40mm
- Thru-bore or hollow-bore styles
- Industrial-grade, heavy-duty housing
- State-of-the-art Opto-ASIC circuitry
-
Features
- Standard Size 36mm package
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven turns counting technology—no gears or batteries
- Flex mount eliminates couplings and is ideal for motors or shafts
-
Features
- Up to 14 Bits of Single-Turn Resolution
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Retains Absolute Position After a Power Outage
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
- 8-decade LCD display (colour: red, green, yellow)
- Resistive touchscreen
- Standard housing with 96 x 48 mm and IP65 protection
- Intuitive and easy parameterization by plain text and touchscreen
- Numerous functions such as scaling, filter, zero offset, counting direction etc.
- Linearization with 24 interpolation points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 4 potential-free changeover relay outputs
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard or front BCD decade switch
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- 2 x 6 control outputs für HTL / PNP signals
- Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 1 MHz
- 2 encoder outputs, short-circuit-proof [TTL / RS422]
- Power supply 12 ... 30 VDC
- Current consumption (unloaded) 30 mA
- Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
- Operation temperature: 0 ... 60 °C (32 ... 140°F)
- Latency time < 250ns
- Channel switching < 1 ms
- Open plastic housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
- Input frequency 750 kHz [TTL] or 300 kHz [HTL]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
- Power supply optionally 5 VDC or 10 ... 30 VDC
- Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
-
Features
- 2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
- 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
- 2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
- Power supply 12 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling and bit blanking
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 5 / 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling, bit blanking and wire break monitoring
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined
Page load link