Skip to content
-
Features
- Low profile—40mm
- Thru-bore or hollow-bore styles
- Industrial-grade, heavy-duty housing
- State-of-the-art Opto-ASIC circuitry
-
Features
- Standard Size 36mm package
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven turns counting technology—no gears or batteries
- Flex mount eliminates couplings and is ideal for motors or shafts
-
Features
- Up to 14 Bits of Single-Turn Resolution
- SSI and CANopen Communications
- 58 mm Diameter
- Durable Magnetic Technology
- Retains Absolute Position After a Power Outage
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
- 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
- 2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
- Power supply 12 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- 1 SSI input (10 … 32 bit)
- for single-turn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
- Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
- Pulse input in format A, B, Z [HTL]
- Input frequency up to 1 MHz
- Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
- Pulse output in format A, B, Z [HTL]
- Power supply 9 ... 30 VDC
- Settings via DIL switches
- Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
- Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
- Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
- External HTL signals for various functions
- Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
- Snap-on housing for top-hat rail (acc. EN 60715)
- Dimension (B x H X T) 22,5 x 102 x 102 mm
-
Features
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- SSI clock frequency up to 1 MHz
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 nsec.
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW217)
- Power supply 10 ... 30 VDC (for LW217-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW218)
- Power supply 10 ... 30 VDC (for LW218-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Glass fibre cables are available ready-assembled
-
Features
- 4 pulse inputs with format A, /A, B, /B [RS422]
- 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
- 8 control inputs for PNP signals [10 ... 30 VDC]
- 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
- Short loop time (depending on application)
- Power supply 18 ... 35 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via Windows operator software (free of charge)
- OnBoard interfaces: RS232 and CANopen
-
Features
- High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
- High level of internal safety (detection of internal errors and failures of the device components)
- 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- 6 logical inputs for PNP signals [10 ... 30 VDC]
- Input frequency up to 500 kHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 forced-guided redundant output relays with potential free change-over contact
- Serial interface RS232 and RS485
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- Setup by keys or PC via serial RS232 Interface
- Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 20-bit parallel input with format BCD, binary or Gray-Code
- Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
- 4 status outputs, with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Power supply 10 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Serial RS232 / RS485 interface
-
Features
- Pulse input with format A, B, Z [HTL] (10 ... 30 V)
- Input frequency max. 200 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422 / TTL]
- Power supply 5 VDC
- Converts HTL levels (A / B / Z) in TTL / RS422, incl. the inverted signals
- Converts also static/separate directional information into a dual channel A / B signal with a 90° phase shift
- Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
-
Features
- Pulse input with format A, /A, B, /B, Z, /Z [TTL / RS422]
- Input frequency max. 200 kHz
- Pulse output with format A, B, Z [HTL]
- Power supply 10 ... 30 VDC
- Converts TTL / RS422 signals (A, /A, B, /B, Z, /Z) in HTL format with an output level of 10 ... 30 VDC
- Generates additionally an A / B directional information with 90° phase shift‚ a static HIGH / LOW directional signal or separate directional pulses
- Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
Page load link