Skip to content
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 500 kHz
2 output relays with potential-free change-over contact (forward, reward and zero motion)
2 transistor outputs with High-Side-Driver, short-circuit-proof
Power supply 17 ... 30 VDC
Snap-on housing for top hat rail (according to EN 60715)
DIL switch for setup of input characteristic and definition of standstill
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
14 Bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 fast transistor switching outputs [PNP]
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
High level of internal safety (detection of internal errors and failures of the device components)
2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
6 logical inputs for PNP signals [10 ... 30 VDC]
Input frequency up to 500 kHz
4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
4 forced-guided redundant output relays with potential free change-over contact
Serial interface RS232 and RS485
Power supply 24 VAC and 17 ... 40 VDC
Compact norm panel housing
6 digits LED display with 15 mm height
Display range -199999 ... 999999
Setup by keys or PC via serial RS232 Interface
Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
Power supply 18 ... 30 VDC
Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
Simple parameterization via the OS6.0 user interface
Serial RS232 / RS485 interface
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
USB interface and RS232/RS485 interface for configuration and serial readout
Features
Suitable for display units with front dimensions 96 x 48 mm
(fits not to Profibus indicator PB340)
Protection class IP65
Features
To increase the protection class in dusty or wet environments, several types of protection caps are available for motrona units.
Some of the elastic and transparent plastic caps allow you to operate the keypad or to set the thumbwheel switches behind the cap, without removing it.
Features
Ultra Miniature Size
High reliability with mounting the Opt-ASIC (by components quantities decreased)
Low torque and low inertia
High signal accuracy
Type: 12SA
Pulse: 100-256
Outer Diameter: φ12
Ingress Protection: IP00
Features
Ultra Miniature Size
Shaft Diameter of 2.5mm available
Type: 18M
Pulse: 200-1600
Outer Diameter: φ18
Features
Ultra Miniature Size
A shaft Diameter of 2.5mm is available
Type: 18S
Pulse: 100-1600
Outer Diameter: φ18
Ingress Protection: IP50
Features
Compact size for general purpose
Type: 38H
Pulse: 100-4096
Outer Diameter: φ38
Ingress Protection: IP50
Features
Compact size for general purpose
Type: 38S
Pulse: 100-4096
Outer Diameter: φ38
Ingress Protection: IP50
Features
Compact size for general purpose
Type: 38SG
Pulse: 100-2048
Outer Diameter: φ38
Ingress Protection: IP50
Page load link