Skip to content
-
Features
- Industry-standard Size 20 (50.8mm diameter) stainless steel package
- Flange and servo mounting
- Up to 30,000 PPR
- 80 lb maximum axial and radial shaft loading
- IP67 sealing available
-
Features
- Industry-standard Size 58 (58mm diameter) stainless steel package
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- 100° C operating temperature available
- IP65 sealing available
- Manufactured in Food Grade Stainless Steel
-
Features
- C-Face thru-bore encoder with stainless steel housing
- Fits NEMA Size 56C thru 184C motor faces (4.5" AK)
- Slim profile—only 25.4mm deep
- Incorporates Opto-ASIC technology
- Resolutions to 4096 PPR
-
Features
- Standard Size 25 package (2.5")
- Resolutions up to 12-bit (4096 counts)
- Incorporates Opto-ASIC technology
- Industrial-grade, heavy-duty housing
- Optional IP67 seal
-
Features
- Standard size 36 mm package (1.42")
- Durable magnetic technology
- Up to 14 bits of single-turn resolution
- SSI and CANopen communications
- Proven new turns counting technology — no gears or batteries
-
Features
- Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
- Stainless steel shaft and ball bearing - ball bearing with Simmer ring
- Rotor with shaft and permanent magnet mounted in pre-chamber
- Sensor circuit consisting of ASIC
- Hall elements and interface electronics in enclosed main chamber
- Housing protection type IP 69K additionally cast
- Electrical connection via cable (open cable ends)
-
Features
- Interface: SSI
- Design: 42mm
- Housing Material: Aluminium, stainless steel
- Flange & Shaft: Synchroniser flange
- Resolution: 4096 steps/360°<)
- Code type: Binary, Gray (optional)
- Electrical connection: Cable 1m
- Electrical and/or mechanical variant: Basic version
-
Features
- Robust aluminium or stainless steel housing (wall thicknesses up to 5 mm)
- Stainless steel shaft and ball bearing - ball bearing with Simmer ring
- Rotor with shaft and permanent magnet mounted in pre-chamber
- Sensor circuit consisting of ASIC
- Hall elements and interface electronics in enclosed main chamber
- Housing protection type IP 69K additionally cast
- Electrical connection via cable (open cable ends)
-
Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- Preset range: 6 digits or 5 digits with sign
- DIL-switch for set up of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- DIL-switch for setup of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.12 ")
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
- 8-decade LCD display (colour: red, green, yellow)
- Resistive touchscreen
- Standard housing with 96 x 48 mm and IP65 protection
- Intuitive and easy parameterization by plain text and touchscreen
- Numerous functions such as scaling, filter, zero offset, counting direction etc.
- Linearization with 24 interpolation points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- EtherCAT interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- EtherNET/IP interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling and bit blanking
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 5 / 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling, bit blanking and wire break monitoring
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Incremental input with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
Page load link