• Features

    • SSI input  with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
    • Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse input in format A, B, Z [HTL]
    • Input frequency up to 1 MHz
    • Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse output in format A, B, Z [HTL]
    • Power supply 9 ... 30 VDC
    • Settings via DIL switches
    • Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
    • Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
    • Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
    • External HTL signals for various functions
    • Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Dimension (B x H X T) 22,5 x 102 x 102 mm
  • Features

    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • SSI clock frequency up to 1 MHz
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout
Go to Top