Skip to content
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- Preset range: 6 digits or 5 digits with sign
- DIL-switch for set up of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- DIL-switch for setup of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.12 ")
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- EtherCAT interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- EtherNET/IP interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Page load link