Skip to content
-
Features
- Industry-standard Size 20 (50.8mm diameter) stainless steel package
- Flange and servo mounting
- Up to 30,000 PPR
- 80 lb maximum axial and radial shaft loading
- IP67 sealing available
-
Features
- Industry-standard Size 58 (58mm diameter) stainless steel package
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- 100° C operating temperature available
- IP65 sealing available
- Manufactured in Food Grade Stainless Steel
-
Features
- C-Face thru-bore encoder with stainless steel housing
- Fits NEMA Size 56C thru 184C motor faces (4.5" AK)
- Slim profile—only 25.4mm deep
- Incorporates Opto-ASIC technology
- Resolutions to 4096 PPR
-
Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 4 potential-free changeover relay outputs
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard or front BCD decade switch
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 1 Strain gauge input
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 4 pulse inputs with format A, /A, B, /B [RS422]
- 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
- 8 control inputs for PNP signals [10 ... 30 VDC]
- 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
- Short loop time (depending on application)
- Power supply 18 ... 35 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via Windows operator software (free of charge)
- OnBoard interfaces: RS232 and CANopen
Page load link