Skip to content
-
Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
- 8-decade LCD display (colour: red, green, yellow)
- Resistive touchscreen
- Standard housing with 96 x 48 mm and IP65 protection
- Intuitive and easy parameterization by plain text and touchscreen
- Numerous functions such as scaling, filter, zero offset, counting direction etc.
- Linearization with 24 interpolation points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling and bit blanking
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single-turn and multi-turn encoders with 10 … 32 Bit
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 5 / 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes such as scaling, bit blanking and wire break monitoring
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Incremental input with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent colour variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
- Power supply 18 ... 30 VDC
- Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
- Simple parameterization via the OS6.0 user interface
- Serial RS232 / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Control input „Error Release“ for PNP signals [10 ... 30 VDC]
- Input frequency up to 400 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
- Output frequency up to 4 MHz [RS422]
- Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Adjustable multiplier for interpolation rates from 1:5 to 1:50
- Adjustable divider 1:1 – 1:255 to reduce the output frequency
-
Features
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
- Power supply 17 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Power supply 17 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardised switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -199999 ... 999999 with 6 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 4 preselector switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardised switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -199999 ... 999999 with 6 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
Page load link