Skip to content
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy connection of the modules
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
2 x 6 control outputs für HTL / PNP signals
Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 1 MHz
2 encoder outputs, short-circuit-proof [TTL / RS422]
Power supply 12 ... 30 VDC
Current consumption (unloaded) 30 mA
Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
Operation temperature: 0 ... 60 °C (32 ... 140°F)
Latency time < 250ns
Channel switching < 1 ms
Open plastic housing for top-hat rail (according to EN 60715)
LEDs for indication of the input pulses
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
Input frequency 750 kHz [TTL] or 300 kHz [HTL]
2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
Power supply optionally 5 VDC or 10 ... 30 VDC
Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
Features
2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
2 control inputs for HTL / PNP signals [10 ... 30 VDC]
2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
BUS interface for quick and easy expansion of the number of outputs
Power supply 10 ... 30 VDC
Signal delay time 160 ns
Input level at RS422 / TTL (differential voltage > 0.5 V),
Input level at HTL differential (differential voltage > 2 V),
Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling and bit blanking
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
5 / 24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling, bit blanking and wire break monitoring
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined
Features
4 pulse inputs with format A, /A, B, /B [RS422]
4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
8 control inputs for PNP signals [10 ... 30 VDC]
4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
Short loop time (depending on application)
Power supply 18 ... 35 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via Windows operator software (free of charge)
OnBoard interfaces: RS232 and CANopen
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent colour variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
Incremental input with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent colour variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
Power supply 17 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC
Features
Wide temperature range
Superior environment resistance
Vibration: 196m/s2{20G} at 10Hz .500Hz, for 2 hours to each of three axes.
Shock: 981m/s2{100G} for 6ms, 3 times to each of 6 axes, 18 times in total
Humidity: 90% RH or above at 60°C
High-speed rotation
High reliability - Extremely long life and high reliability are assured by the structure of mechanical parts and automated coil incorporation.
Absolute position detection
Long-distance transmission - Robustness against noise enables long-distance transmission
Capable of compact incorporation - The use of built-in types of Smartsyn minimizes the housings of motors. Best suited for compact design
Low cost
Multipolarization is possible by increasing the multiplication factor of angle
Features
Wide temperature range
Superior environment resistance
Vibration: 196m/s2{20G} at 10Hz .500Hz, for 2 hours to each of three axes.
Shock: 981m/s2{100G} for 6ms, 3 times to each of 6 axes, 18 times in total
Humidity: 90% RH or above at 60°C
High-speed rotation
High reliability - Extremely long life and high reliability are assured by the structure of mechanical parts and automated coil incorporation.
Absolute position detection
Long-distance transmission - Robustness against noise enables long-distance transmission
Capable of compact incorporation - The use of built-in types of Smartsyn minimizes the housings of motors. Best suited for compact design
Low cost
Multipolarization is possible by increasing the multiplication factor of angle
Features
Wide temperature range
Superior environment resistance
Vibration: 196m/s2{20G} at 10Hz .500Hz, for 2 hours to each of three axes.
Shock: 981m/s2{100G} for 6ms, 3 times to each of 6 axes, 18 times in total
Humidity: 90% RH or above at 60°C
High-speed rotation
High reliability - Extremely long life and high reliability are assured by the structure of mechanical parts and automated coil incorporation.
Absolute position detection
Long-distance transmission - Robustness against noise enables long-distance transmission
Capable of compact incorporation - The use of built-in types of Smartsyn minimizes the housings of motors.
Best suited for compact design
Low cost
Multipolarization is possible by increasing the multiplication factor of the angle.
Page load link