Skip to content
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 pulse inputs with format A, /A, B, /B [RS422]
- 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
- 8 control inputs for PNP signals [10 ... 30 VDC]
- 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
- Short loop time (depending on application)
- Power supply 18 ... 35 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via Windows operator software (free of charge)
- OnBoard interfaces: RS232 and CANopen
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
- 9600 Bit/s ... 12 MBit/s Baud rates
- SUB-D-9-pin female, galvanically isolated
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
- 100 MBit/s Vollduplex
- 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
-
Features
- 1 connector Sub-D-9 (male)
- 1 connector Sub-D-9 (female)
- cable length 3 m (approx. 10 feet)
-
Features
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Power supply 17 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- USB cable for connection between PC and the Motrona unit UZ210
- Both connectors are type A
- Cable length 2 m (approx. 6.5 feet)
-
Features
- USB cable for connection between PC operator software and Motrona DS device
- USB connector type A on type B
- Length 1,8 m
-
Features
- USB cable for connection between PC and Motrona devices of the series IV/FU/PV/ZU210 and IP/FP/PP/ZP210
- USB connector type A on type Mini B
- Length 1,8 m
-
Features
- Ultra Miniature Size
- High reliability with mounting the Opt-ASIC (by components quantities decreased)
- Low torque and low inertia
- High signal accuracy
- Type: 12SA
- Pulse: 100-256
- Outer Diameter: φ12
- Ingress Protection: IP00
-
Features
- Ultra Miniature Size
- Shaft Diameter of 2.5mm available
- Type: 18M
- Pulse: 200-1600
- Outer Diameter: φ18
-
Features
- Ultra Miniature Size
- A shaft Diameter of 2.5mm is available
- Type: 18S
- Pulse: 100-1600
- Outer Diameter: φ18
- Ingress Protection: IP50
-
Features
- Compact size for general purpose
- Type: 38H
- Pulse: 100-4096
- Outer Diameter: φ38
- Ingress Protection: IP50
Page load link