Features
- Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
- Power supply 24 VDC
- Miniature norm panel housing
- 5 digits LED display with 8 mm height
- Display range -19999 ... 99999, adjustable zero and full-scale value
- Latch input to freeze the display, minimum/maximum record memory
- Easy to set up with only two front keys and menu support
- Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
- Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
-
Features
- 2 universal 16-bit analogue inputs for ±10 V or 0/4 … 20 mA
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- High accuracy reference output 10 V for potentiometers > 1 kOhm
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
- Numerous features, e. g. tara, filters, averaging
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
- 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
- SUB-D-9-pin male, galvanically isolated
-
Features
- USB to RS232 converter (compatible with all existing Windows versions)
- Serial RS232 cable (for connection between the converter and motrona unit)
- One connector Sub-D-9 (male)
- One connector Sub-D-9 (female)
- Length 3 m (approx. 10 feet)
- Windows driver CD enclosed
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Single channel pulse input [HTL]
- Input frequency up to 20 kHz
- Programmable input filter for mechanical input contacts
- Power supply 24 VDC
- Miniature norm panel housing
- 6 digits LED display with 8 mm height
- Display range -199999 ... 999999
- Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-functional device for speed, position, timer, counter or velocity application
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- 2 Incremental inputs with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- Power supply 18 ... 30 VDC
- 5 / 24 VDC auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-functional device for speed, process time, timer, counter or velocity application
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- Sub-D-9 connectors (male) on both sides
- cable length 10 cm (approx. 3.4")
-
Features
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 nsec.
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW217)
- Power supply 10 ... 30 VDC (for LW217-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW218)
- Power supply 10 ... 30 VDC (for LW218-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Glass fibre cables are available ready-assembled
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
- 9600 Bit/s ... 12 MBit/s Baud rates
- SUB-D-9-pin female, galvanically isolated
-
Features
- Internal power supply 3,3 V
- Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
- 100 MBit/s Vollduplex
- 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via mMotrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard or BCD decade switch on the front
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
- Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")