Skip to content
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Maximum shaft speed 5000 rpm
Maximum shaft load
- radial: 10 N
Accuracy ± 7.5 arc. sec; ± 5.0 arc. sec
Starting torque at 20°C ≤ 0.01 Nm
Rotor moment of inertia < 20x10-6 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 0.7 kg
Operating temperature 0...+50°C
Storage temperature -30...+80°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: ≤ 30 N
- radial: ≤ 30 N
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 3.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.1 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 3.600.000
Line number on disc (z) 36000
Reference signal
- 1 per shaft revolution
- 36 per shaft revolution
- 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.0 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.5 Nm
Rotor moment of inertia < 0.9x10-3 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Permissible mech. speed ≤ 3000 rpm
Max. operating speed 600 to 1000 rpm
Accuracy grades ± 5.0 arc. sec
Permissible shaft runout - axial: 0.02 mm
- radial: ± 0.02 mm
Starting torque at 20°C ≤ 0.08 Nm
Rotor moment of inertia < 0.6x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 1.2 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Features
Absolute measuring method
Hollow shaft diameter (up to 50 mm)
Integrated stator coupling
Simple installation
Typical field of application
Rotational axes with reduced accuracy requirements
Features
Absolute measuring method
Large hollow shaft diameter (up to 100 mm)
Integrated stator coupling
Compact size for limited installation space
System accuracy includes the deviation caused by the shaft connection
Outstanding dynamic response
Simple installation
Typical field of application
Rotary tables
Swivel heads
Features
Incremental measuring method
Solid shaft
Separate shaft coupling for large mounting tolerances
System accuracy does not include the deviation caused by the shaft connection
Typical field of application
Features
Incremental measuring method
Large hollow shaft diameter (up to 60 mm)
Integrated stator coupling
Compact size for limited installation space
System accuracy includes the deviation caused by the shaft connection
Outstanding dynamic response
Simple installation
Typical field of application
Rotary tables
Swivel heads
Features
Large hollow shaft diameter (up to 10 m with a scale tape)
High shaft speeds up to 20,000 rpm
No additional starting torque from shaft seals
Segment versions
Also available with Functional Safety Modular angle encoders with optical scanning are available with various graduation carriers:
ERP/ERO: Glass circular scale with hub
ERA/ECA 4000: Steel drum
ERA 7000/8000: Steel scale tape
Typical field of application
High-resolution rotary axes with high reproducibility
Very high number of signal periods
Small mounting space
Small interpolation error and low signal noise
Features
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Display of alarm and error codes
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Simple parameterization of motrona safety devices
Editing, saving and loading of parameters
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Internal power supply 3,3 V
Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
SUB-D-9-pin male, galvanically isolated
Features
USB to RS232 converter (compatible with all existing Windows versions)
Serial RS232 cable (for connection between the converter and motrona unit)
One connector Sub-D-9 (male)
One connector Sub-D-9 (female)
Length 3 m (approx. 10 feet)
Windows driver CD enclosed
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)