Skip to content
Features
Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
Power supply 24 VDC
Miniature norm panel housing
5 digits LED display with 8 mm height
Display range -19999 ... 99999, adjustable zero and full-scale value
Latch input to freeze the display, minimum/maximum record memory
Easy to set up with only two front keys and menu support
Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
Features
2 universal 16-bit analog inputs for ±10 V or 0/4 … 20 mA
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
High accuracy reference output 10 V for potentiometers > 1 kOhm
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
Numerous features, e. g. Ttara, filters, averaging
Linearization with 24 control points
Option IO (= IO-Link Device)
Data transfer via COM3 (230,4 kBaud)
Cycle times < 3 msec
Process data IN 32 Byte (6 x process values from AX350):
- Analog value 1 (scaled / linearized) and unit
- Analog value 2 (scaled / linearized) and unit
- Analog value 1 (scaled / linearized) with totalisation and unit
- Analog value 2 (scaled / linearized) with totalisation and unit
- Shortcut analogue value 1 (scaled / linearized) with analogue value 2 (scaled / linearized) and unit
- Shortcut totalisator analogue value 1 (scaled / linearized) with totalisator analogue value 2 (scaled / linearized) and unit
Process data Out 8 Byte (2 x IO-Link process values to AX350):
- IOL process value Out 1 with scaling, adjustable decimal point and programmable units
- IOL process values Out 2 with scaling, adjustable decimal point and programmable units
Combinable with further options:
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Features
Strain gauge input, 6-wire connection
Input pt100 and thermocouples (J and K)
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
Adjustable bridge voltage 3 VDC to 10 VDC
1 … 10 mV sensitivity
Standard installation housing with 96 x 48 mm and protection class IP65
Bright and high-contrast graphic display with event-dependent color variants
Emulation of a 7-segment display with symbols and units
Intuitive and simple parameterization through plain text and touchscreen
Numerous functions such as tare, filter, averaging
Linearization with 24 support points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Option IO: IO-Link Device V1.1
Options can be combined.
Features
Single channel pulse input [HTL]
Input frequency up to 20 kHz
Programmable input filter for mechanical input contacts
Power supply 24 VDC
Miniature norm panel housing
6 digits LED display with 8 mm height
Display range -199999 ... 999999
Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
2 Incremental inputs with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
Power supply 18 ... 30 VDC
5 / 24 VDC auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, process time, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distances up to 3000 meters
Power supply 5 VDC (for LW214)
Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW215)
Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW216)
Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 Error input (LW217) resp. 1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 nsec.
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW217)
Power supply 10 ... 30 VDC (for LW217-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW218)
Power supply 10 ... 30 VDC (for LW218-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Glass fibre cables are available ready-assembled
Features
4 pulse inputs with format A, /A, B, /B [RS422]
4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
8 control inputs for PNP signals [10 ... 30 VDC]
4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
Short loop time (depending on application)
Power supply 18 ... 35 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via Windows operator software (free of charge)
OnBoard interfaces: RS232 and CANopen
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
4 preselector switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
2 pre-selection switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
4 preselector switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 6 decades with 15 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Page load link