• Features

    • Type: Photoelectric rotary encoder (converts rotational movement into electrical signals)
    • Function: Incremental (tracks changes in rotation rather than absolute position)
    • Diameter: Compact size of 28 mm
    • High resolution: Up to 25,000 output pulses per revolution (providing detailed rotational information)
    • Benefit: Well-suited for applications with limited space due to its small size
  • Features

    • Number of output pulses per revolution 100-108000 ppr
    • Maximum shaft speed 10000 rpm
    • The permissible motion of the shaft - axial: ± 0.5 mm - radial: ± 0.05 mm
    • Accuracy (T1-period lines on disc in arc. sec) ± 0.1T1 arc. sec
    • Starting torque at 20°C ≤ 0.025 Nm
    • Rotor moment of inertia < 1.5x10-4 kgm2
    • Protection (housing) (IEC 529) IP64
    • Protection (shaft side) (IEC 529) IP64
    • Maximum weight without cable 0.3 kg
    • Operating temperature -10...+70°C
    • Storage temperature -30...+80°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (5 ms) ≤ 1000 m/s²
  • Features

    • Miniature size (38.1mm diameter)
    • Up to 30,000 PPR
    • Servo or flange mounting
    • 1 MHz frequency response available
    • Extended temperature operating range available
  • Features

    • Standard Size 58 mounting (58 mm diameter)
    • Up to 30,000 PPR
    • 36 Kg max. Axial and radial shaft loading
    • High-temperature option (100° C)
    • IP65 sealing available
  • Features

    • Standard Size 58 mounting (58 mm diameter)
    • Up to 30,000 PPR
    • 36 Kg max. Axial and radial shaft loading
    • High temperature option (100° C)
    • IP65 sealing available
  • Features

    • Power supply 10 ... 30 VDC
    • Compact norm panel housing
    • Preset range: 6 digits or 5 digits with sign
    • DIL-switch for set up of the transmission parameters
    • Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
  • Features

    •  Power supply 10 ... 30 VDC
    • Compact norm panel housing
    • 6 digits LED display with 15 mm height
    • Display range -199999 ... 999999
    • DIL-switch for setup of the transmission parameters
    • Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.12 ")
  • Features

    • Pulse input with format A, B, 90° [HTL], single channel as an option
    • HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
    • Input frequency up to 250 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, position, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • 2 Incremental inputs with format A, /A, B, /B
    • Differential, single-ended HTL / RS422
    • Input frequency up to 1 MHz
    • Power supply 18 ... 30 VDC
    • 5 / 24 VDC auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, process time, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.
  • Features

    • EtherCAT interface
    • 3 control inputs for remote release
    • Power supply 18 ... 30 VDC
    • Norm panel housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols, units and bargraph
    • Intuitive and simple parameterization through plain text and touchscreen
  • Features

    • EtherNET/IP interface
    • 3 control inputs for remote release
    • Power supply 18 ... 30 VDC
    • Norm panel housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols, units and bargraph
    • Intuitive and simple parameterization through plain text and touchscreen
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 2 x 6 control outputs für HTL / PNP signals
    • Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 1 MHz
    • 2 encoder outputs, short-circuit-proof [TTL / RS422]
    • Power supply 12 ... 30 VDC
    • Current consumption (unloaded) 30 mA
    • Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
    • Operation temperature: 0 ... 60 °C (32 ... 140°F)
    • Latency time < 250ns
    • Channel switching  < 1 ms
    • Open plastic housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
    • Input frequency 750 kHz [TTL] or 300 kHz [HTL]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
    • Power supply optionally 5 VDC or 10 ... 30 VDC
    • Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
  • Features

    • 2 pulse inputs with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
    • 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
    • 2 output channels with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
Go to Top