Skip to content
Features
Industry-standard Size 20 (50.8mm diameter) stainless steel package
Flange and servo mounting
Up to 30,000 PPR
80 lb maximum axial and radial shaft loading
IP67 sealing available
Features
Industry-standard Size 58 (58mm diameter) stainless steel package
Up to 30,000 PPR
36 Kg max. Axial and radial shaft loading
100° C operating temperature available
IP65 sealing available
Manufactured in Food Grade Stainless Steel
Features
C-Face thru-bore encoder with stainless steel housing
Fits NEMA Size 56C thru 184C motor faces (4.5" AK)
Slim profile—only 25.4mm deep
Incorporates Opto-ASIC technology
Resolutions to 4096 PPR
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
8-decade LCD display (colour: red, green, yellow)
Resistive touchscreen
Standard housing with 96 x 48 mm and IP65 protection
Intuitive and easy parameterization by plain text and touchscreen
Numerous functions such as scaling, filter, zero offset, counting direction etc.
Linearization with 24 interpolation points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
2 Incremental inputs with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
Power supply 18 ... 30 VDC
5 / 24 VDC auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, process time, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
Start-stop interface for absolute transducers and magnetostrictive sensors
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via operator software OS6.0
Serial RS232- / RS485 interface
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
Start-stop interface for absolute transducers and magnetostrictive sensors
USB interface and RS232/RS485 interface for configuration and serial readout
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
1 incremental input (A, /A, B, /B)
for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling and bit blanking
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
5 / 24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling, bit blanking and wire break monitoring
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
Power supply 18 ... 30 VDC
Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
Simple parameterization via the OS6.0 user interface
Serial RS232 / RS485 interface
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
USB interface and RS232/RS485 interface for configuration and serial readout
Features
Suitable for display units with front dimensions 96 x 48 mm
(fits not to Profibus indicator PB340)
Protection class IP65
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC
Features
To increase the protection class in dusty or wet environments, several types of protection caps are available for motrona units.
Some of the elastic and transparent plastic caps allow you to operate the keypad or to set the thumbwheel switches behind the cap, without removing it.
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
4 preselector switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
2 pre-selection switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Page load link