Skip to content
Features
MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
The number of successive axes can be extended arbitrarily via a cascading output.
MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
PROFIBUS connection possible via gateway PB251 (see accessories)
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
8-decade LCD display (colour: red, green, yellow)
Resistive touchscreen
Standard housing with 96 x 48 mm and IP65 protection
Intuitive and easy parameterization by plain text and touchscreen
Numerous functions such as scaling, filter, zero offset, counting direction etc.
Linearization with 24 interpolation points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
Start-stop interface for absolute transducers and magnetostrictive sensors
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via operator software OS6.0
Serial RS232- / RS485 interface
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
Start-stop interface for absolute transducers and magnetostrictive sensors
USB interface and RS232/RS485 interface for configuration and serial readout
Features
Control input with format [HTL]
2 SSI inputs with format [RS422]
Cutt-off frequency 100 kHz ... 1 MHz
2 encoder inputs, short-circuit-proof
1 SSI output with format [RS422]
Power supply 12 ... 30 V DC
Current consumption (unloaded) 50 mA
Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
Delay / Output / Input100 ns
Operation temperature : 0 ... 45 °C (32 ... 113 °F)
SSI pause time min. 25 ns
Switching time is synchronized automatically with the next SSI break
Cascadable for more SSI encoders
All connections via pluggable screw terminal block
Snap-on housing for top-hat rail (according to EN 60715)
LEDs for indication of the input pulses
Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
Plastic housing incl. plug
Features
1 incremental input (A, /A, B, /B)
for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
1 SSI input (10 … 32 bit)
for single-turn and multiturn encoders
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
Start-stop interface for absolute transducers and magnetostrictive sensors
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
SSI clock frequency up to 1 MHz
Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via operator software OS6.0
Serial RS232- / RS485 interface
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
Start-stop interface for absolute transducers and magnetostrictive sensors
USB interface and RS232/RS485 interface for configuration and serial readout
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling and bit blanking
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
SSI clock frequencies up to 1 MHz
Master or Slave operation
For single-turn and multi-turn encoders with 10 … 32 Bit
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
5 / 24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes such as scaling, bit blanking and wire break monitoring
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distances up to 3000 meters
Power supply 5 VDC (for LW214)
Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW215)
Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW216)
Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 Error input (LW217) resp. 1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 nsec.
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW217)
Power supply 10 ... 30 VDC (for LW217-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW218)
Power supply 10 ... 30 VDC (for LW218-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Glass fibre cables are available ready-assembled
Features
High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
High level of internal safety (detection of internal errors and failures of the device components)
2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
6 logical inputs for PNP signals [10 ... 30 VDC]
Input frequency up to 500 kHz
4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
4 forced-guided redundant output relays with potential free change-over contact
Serial interface RS232 and RS485
Power supply 24 VAC and 17 ... 40 VDC
Compact norm panel housing
6 digits LED display with 15 mm height
Display range -199999 ... 999999
Setup by keys or PC via serial RS232 Interface
Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
Features
20-bit parallel input with format BCD, binary or Gray-Code
Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
4 status outputs, with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
Power supply 10 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Serial RS232 / RS485 interface
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 output relays with potential-free changeover contact
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
4 preselector switches on the front
Serial RS232 interface
Dimensions W x H x D = 96 x 96 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardized switch panel housing
LED display 8 decades with 10 mm digit height
Display range -19999999 ... 99999999 with 8 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Features
2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
Input frequency up to 1MHz
4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
4 programmable limits
Power supply 24 VAC and 17 ... 40 VDC
Standardised switch panel housing
LED display 6 decades with 15 mm digit height
Display range -199999 ... 999999 with 6 decades
Serial RS232 interface
Dimensions W x H x D = 96 x 48 x 140 mm
Page load link