Skip to content
-
Features
- Miniature size (38.1mm diameter)
- Up to 30,000 PPR
- Servo or flange mounting
- 1 MHz frequency response available
- Extended temperature operating range available
-
Features
- Standard Size 58 mounting (58 mm diameter)
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- High-temperature option (100° C)
- IP65 sealing available
-
Features
- Standard Size 58 mounting (58 mm diameter)
- Up to 30,000 PPR
- 36 Kg max. Axial and radial shaft loading
- High temperature option (100° C)
- IP65 sealing available
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Cutting length specification via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 4 potential-free changeover relay outputs
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Cutting length specification via BCD decade switch on the front
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy connection of the modules
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
- 4 control inputs for HTL, PNP signals [10 ... 30 VDC]
- Input and output frequency up to 1 MHz
- 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
- Power supply 9 ... 30 VDC
- Snap-on housing for top-hat rail (acc. EN 60715)
- Multiplier/divisor adjustable as quotient F1 / F2
- Multiplication/division without cumulative residual errors
- Additional functions such as jog, trim, offset and reference
Page load link