Skip to content
Features
Type: Non-contact magnetic linear encoder (measures displacement without physical contact)
Measuring length: Up to 50 meters
Function: Converts linear movements of machine components into electrical signals with information about:
Value: Distance travelled
Direction: Forward or backward movement
Durability: Designed for harsh industrial environments and resistant to various contaminants and physical impacts.
Components:
Metal-based magnetic band (MP): Stores the encoded information
Reading head: Detects the magnetic field variations on the band and converts them into electrical signals
Profile rail (PS) with protective band: Provides mounting and protects the reading head
Features
Type: Photoelectric linear displacement measuring device (measures changes in position)
Measuring length: Up to 2.040 mm
Grating period: Two options available: ±20 µm or ±40 µm (determines the smallest detectable movement)
Accuracy: Up to ±3 µm (indicates the encoder's closeness to the actual displacement)
Features
Measuring length: Up to 3.240 mm
Accuracy: Up to ±5 µm within any meter of its measuring length
Grating periods: Available in two options: ±20 µm and ±40 µm
Features
Similar to the L18 series: Shares most functionalities and specifications with the L18 series encoders.
Different housing fixation: Requires distinct mounting methods compared to the L18 series.
Improved thermal behaviour: More stable performance under different temperatures.
Features
Type: Photoelectric modular linear encoder
Measuring length:
Up to 20,000 mm (20 meters)
Can be even longer with special order
Accuracy: Up to ±3 µm
Features
Type: Incremental linear displacement measuring device (measures changes in position)
Measuring length: Up to 3.240 mm
Accuracy: Up to ±3 µm within any meter of its measuring length (accuracy scales with length)
Vibration resistance: More resistant to vibrations than the L18 series encoders
Features
Similar to the L35 series: Shares most functionalities and specifications with the L35 series encoders.
Different mounting parameters: Requires distinct mounting methods compared to the L35 series.
Measuring length: Up to 3.240 mm.
Enhanced vibration resistance: More resistant to vibrations than the L18 series encoders, making it suitable for applications with higher vibration levels.
Features
Type: Incremental encoder
Thermal behaviour: Reproducible, indicating stability under temperature changes
Reading head: Reversible for flexibility in installation
Measuring length: Up to 3.240 mm
Accuracy: Up to ±3 µm within the measuring length
Features
Type: Incremental encoder
Measuring length: 3.240 mm to 30.040 mm
Grating period: 40 µm
Accuracy: Up to ±10 µm within the measuring length
Features
Type: Photoelectric absolute linear encoder (measures absolute position)
Measuring length: Up to 3.240 mm (customizable)
Interface: SSI or BiSS serial interface for digital communication
Accuracy: Up to ±1 µm high accuracy
Optional incremental track: Provides 1Vpp incremental signal for applications requiring both absolute and incremental position data.
Features
Magnetic absolute linear encoder
MK has a measuring length of up to 50.000 mm
Accuracy can reach up to ±35 μm.
Encoder has two versions of serial interface - SSI or BiSS C
Optionally it can have 2 analog sinusoidal signals with phase shift 90°C and amplitude approx. 1Vpp.
Features
Measuring length: Up to 50,000 mm (50 meters)
Accuracy: Up to ±25 micrometres (μm)
Customizable: Other parameters can be modified to meet specific needs
Features
Converts the movement of key machine parts into electrical signals.
Designed for harsh industrial environments and resistant to various physical and environmental factors.
Magnetic band length can reach up to 50 meters.
Allows for either user-defined reference marks or external zero signal actuator.
LED on the reading head confirms reference mark detection.
Compressed air can be used to clean the rail surface, improving accuracy.
Two output signal options:
PCMT-F: Square-wave with built-in interpolation electronics.
PCMT-AV: Sinusoidal signal requiring external interpolation.
Features
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Display of alarm and error codes
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Simple parameterization of motrona safety devices
Editing, saving and loading of parameters
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
6-wire connection for one strain gauge full bridge sensor
4 control inputs [HTL/PNP]
1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
6-wire connection for two independent strain gauge full bridge sensors
4 control inputs [HTL/PNP]
2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
2 Incremental inputs with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
Power supply 18 ... 30 VDC
5 / 24 VDC auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, process time, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Page load link