Skip to content
Features
5mm Opto-ASIC encoder with a low profile (50.8mm)
Imperial bore sizes range from 0.625” to 1.125”
Metric bore sizes ranging from 6 mm to 28 mm
Single replacement solution for 50.8mm to 88.9mm encoders
Resolutions to 10,000 PPR, frequencies to 1 MHz
Versatile flexible mounting options
RoHS compliant
Corrosion-Resistant Option
Features
58 mm package available in thru-bore or hollow bore
Resolutions from 1 to 65,536 PPR
6 different output types to choose from
32 different waveforms available
Standard and Metric Bore Sizes up to 5/8” and 15 mm
Several Flexible Mounting Options
IP67 Sealing Available
Features
Miniature size (38.1mm diameter)
Up to 30,000 PPR
Flex mounting & large hollow bore option (Up to 14mm)
High-temperature option
Features
Size 25 / 63.5mm Diameter (Hollow Shaft)
Up to 12 Pole Commutation Available
Thru Bore and Blind Bore Options
Simple, Innovative Flexible Mounting System
Incorporates Opto-ASIC Technology
Features
Number of output pulses per revolution 100-108000 ppr
Maximum shaft speed 10000 rpm
Permissible motion of shaft - axial: ± 0.5 mm- radial: ± 0.05 mm
Accuracy (T1-period lines on disc in arc. sec) ± 0.1T1 arc. sec
Starting torque at 20°C ≤ 0.025 Nm
Rotor moment of inertia < 1.5x10-4 kgm2
Protection (housing) (IEC 529) IP64
Protection (shaft side) (IEC 529) IP64
Maximum weight without cable 0.3 kg
Operating temperature -10...+70°C
Storage temperature -30...+80°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (5 ms) ≤ 1000 m/s²
Features
Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
Power supply 24 VDC
Miniature norm panel housing
5 digits LED display with 8 mm height
Display range -19999 ... 99999, adjustable zero and full-scale value
Latch input to freeze the display, minimum/maximum record memory
Easy to set up with only two front keys and menu support
Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
Features
2 universal 16-bit analogue inputs for ±10 V or 0/4 … 20 mA
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
High accuracy reference output 10 V for potentiometers > 1 kOhm
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
Numerous features, e. g. tara, filters, averaging
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Option IO: IO-Link Device V1.1
Features
6-wire connection for one strain gauge full bridge sensor
4 control inputs [HTL/PNP]
1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
6-wire connection for two independent strain gauge full bridge sensors
4 control inputs [HTL/PNP]
2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 500 kHz
2 output relays with potential-free change-over contact (forward, reward and zero motion)
2 transistor outputs with High-Side-Driver, short-circuit-proof
Power supply 17 ... 30 VDC
Snap-on housing for top hat rail (according to EN 60715)
DIL switch for setup of input characteristic and definition of standstill
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
14 Bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 fast transistor switching outputs [PNP]
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
4 control inputs for HTL, PNP signals [10 ... 30 VDC]
Input and output frequency up to 1 MHz
3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
Power supply 9 ... 30 VDC
Snap-on housing for top-hat rail (acc. EN 60715)
Multiplier/divisor adjustable as quotient F1 / F2
Multiplication/division without cumulative residual errors
Additional functions such as jog, trim, offset and reference
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
4 control inputs for PNP signals [10 ... 30 VDC]
Input and output frequency up to 1 MHz
Pulse output with format A, /A, B, /B, Z, /Z and
push-pull characteristic, [5 ... 30 VDC]
Power supply 11 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
LCD backlighted
Setup via keys, RS232
The device multiplies an incoming frequency by a proportional factor F1 and a reciprocal factor F2. The two factors F1 and F2 are adjustable in the range of 0.0005 to 9.9999
All operation modes provide error-free frequency conversion, with full consideration of the A / B phase and direction of the quadrature signals, therefore no cumulative errors, even with continuous changes of directions and vibrations
Zero pulse generator: the frequency multiplier generates at the output an index signal with an adjustable pulse interval, which can be synchronized as needed with the zero pulse at the input
Features
1 Strain gauge input
3 VDC and 10 VDC bridge voltage per sensor connection
1 … 10 mV sensitivity
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse input in format A, B, Z [HTL]
Input frequency up to 1 MHz
Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse output in format A, B, Z [HTL]
Power supply 9 ... 30 VDC
Settings via DIL switches
Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
External HTL signals for various functions
Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
Snap-on housing for top-hat rail (acc. EN 60715)
Dimension (B x H X T) 22,5 x 102 x 102 mm
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distances up to 3000 meters
Power supply 5 VDC (for LW214)
Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW215)
Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW216)
Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 Error input (LW217) resp. 1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 nsec.
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW217)
Power supply 10 ... 30 VDC (for LW217-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW218)
Power supply 10 ... 30 VDC (for LW218-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Glass fibre cables are available ready-assembled
Page load link