Skip to content
-
Features
- Low-cost linear solution
- Imperial and Metric Options
- IP65 sealing available
- Up to 1.27M or 50” Full Stroke Length
-
Features
- Encoder and measuring wheel solution integrated into one compact unit
- Spring-loaded torsion arm makes wheel pressure adjustments a snap
- Easily installed in a vertical, horizontal or upside-down orientation
- Operates over a variety of surfaces at speeds up to 3000 feet per minute
- The integrated module simplifies your system design, reducing cost
-
Features
- Integrated heavy-duty encoder and measuring wheel in one
- Spring-loaded torsion arm for quick wheel pressure adjustments
- Easily installed in a vertical, horizontal or upside-down orientation
- Operates over a variety of surfaces at speeds up to 3000 feet per minute
- Integrated module simplifies system design, reducing cost
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 nsec.
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW217)
- Power supply 10 ... 30 VDC (for LW217-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW218)
- Power supply 10 ... 30 VDC (for LW218-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Glass fibre cables are available ready-assembled
-
Features
- High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
- High level of internal safety (detection of internal errors and failures of the device components)
- 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- 6 logical inputs for PNP signals [10 ... 30 VDC]
- Input frequency up to 500 kHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 forced-guided redundant output relays with potential free change-over contact
- Serial interface RS232 and RS485
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- Setup by keys or PC via serial RS232 Interface
- Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via mMotrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Loop time approx. 250 µs
- Defining incremental dimensions via keyboard or BCD decade switch on the front
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
- Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
- Power supply 18 ... 30 VDC
- Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
- Simple parameterization via the OS6.0 user interface
- Serial RS232 / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- USB interface and RS232/RS485 interface for configuration and serial readout
Page load link