Skip to content
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Maximum shaft speed 5000 rpm
Maximum shaft load
- radial: 10 N
Accuracy ± 7.5 arc. sec; ± 5.0 arc. sec
Starting torque at 20°C ≤ 0.01 Nm
Rotor moment of inertia < 20x10-6 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 0.7 kg
Operating temperature 0...+50°C
Storage temperature -30...+80°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: ≤ 30 N
- radial: ≤ 30 N
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 3.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.1 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 3.600.000
Line number on disc (z) 36000
Reference signal
- 1 per shaft revolution
- 36 per shaft revolution
- 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.0 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.5 Nm
Rotor moment of inertia < 0.9x10-3 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Permissible mech. speed ≤ 3000 rpm
Max. operating speed 600 to 1000 rpm
Accuracy grades ± 5.0 arc. sec
Permissible shaft runout - axial: 0.02 mm
- radial: ± 0.02 mm
Starting torque at 20°C ≤ 0.08 Nm
Rotor moment of inertia < 0.6x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 1.2 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Features
Absolute measuring method
Hollow shaft diameter (up to 50 mm)
Integrated stator coupling
Simple installation
Typical field of application
Rotational axes with reduced accuracy requirements
Features
Absolute measuring method
Large hollow shaft diameter (up to 100 mm)
Integrated stator coupling
Compact size for limited installation space
System accuracy includes the deviation caused by the shaft connection
Outstanding dynamic response
Simple installation
Typical field of application
Rotary tables
Swivel heads
Features
Incremental measuring method
Solid shaft
Separate shaft coupling for large mounting tolerances
System accuracy does not include the deviation caused by the shaft connection
Typical field of application
Features
Incremental measuring method
Large hollow shaft diameter (up to 60 mm)
Integrated stator coupling
Compact size for limited installation space
System accuracy includes the deviation caused by the shaft connection
Outstanding dynamic response
Simple installation
Typical field of application
Rotary tables
Swivel heads
Features
Large hollow shaft diameter (up to 10 m with a scale tape)
High shaft speeds up to 20,000 rpm
No additional starting torque from shaft seals
Segment versions
Also available with Functional Safety Modular angle encoders with optical scanning are available with various graduation carriers:
ERP/ERO: Glass circular scale with hub
ERA/ECA 4000: Steel drum
ERA 7000/8000: Steel scale tape
Typical field of application
High-resolution rotary axes with high reproducibility
Very high number of signal periods
Small mounting space
Small interpolation error and low signal noise
Features
Single channel pulse input [HTL]
Input frequency up to 20 kHz
Programmable input filter for mechanical input contacts
Power supply 24 VDC
Miniature norm panel housing
6 digits LED display with 8 mm height
Display range -199999 ... 999999
Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Page load link