Skip to content
Features
Low-cost linear solution
Imperial and Metric Options
IP65 sealing available
Up to 1.27M or 50” Full Stroke Length
Features
Encoder and measuring wheel solution integrated into one compact unit
Spring-loaded torsion arm makes wheel pressure adjustments a snap
Easily installed in a vertical, horizontal or upside-down orientation
Operates over a variety of surfaces at speeds up to 3000 feet per minute
The integrated module simplifies your system design, reducing cost
Features
Integrated heavy-duty encoder and measuring wheel in one
Spring-loaded torsion arm for quick wheel pressure adjustments
Easily installed in a vertical, horizontal or upside-down orientation
Operates over a variety of surfaces at speeds up to 3000 feet per minute
Integrated module simplifies system design, reducing cost
Features
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Display of alarm and error codes
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Simple parameterization of motrona safety devices
Editing, saving and loading of parameters
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
Solder connection
Metallised plastic enclosure
Mounting screws included
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
Single channel pulse input [HTL]
Input frequency up to 20 kHz
Programmable input filter for mechanical input contacts
Power supply 24 VDC
Miniature norm panel housing
6 digits LED display with 8 mm height
Display range -199999 ... 999999
Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
Features
Pulse input with format A, B, 90° [HTL], single channel as an option
HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
Input frequency up to 250 kHz
3 control inputs for HTL / PNP signals
Power supply 18 ... 30 VDC
24 V auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, position, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputs
Options can be combined.
Features
2 Incremental inputs with format A, /A, B, /B
Differential, single-ended HTL / RS422
Input frequency up to 1 MHz
Power supply 18 ... 30 VDC
5 / 24 VDC auxiliary output for encoder supply
3.78 x 1.89-inch norm panel housing and IP65 protection
Bright and high-contrast display with event-dependent color variations
Emulation of a 7-segment display inclusively icons and units
Intuitive and easy parameterization by plain text and touchscreen
Multi-functional device for speed, process time, timer, counter or velocity application
Operating modes such as scaling, average filter, start-up suppression
Linearization with 24 control points
Options
Option AC: Power supply 115 ... 230 VAC
Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
Option CO: 4 control outputs, serial RS232 interface
Option CR: 4 control outputs, serial RS485 interface
Option RL: 2 relay outputsOptions can be combined.
Features
Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
Start-stop interface for absolute transducers and magnetostrictive sensors
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via operator software OS6.0
Serial RS232- / RS485 interface
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
Start-stop interface for absolute transducers and magnetostrictive sensors
USB interface and RS232/RS485 interface for configuration and serial readout
Features
4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
1 incremental input (A, /A, B, /B)
for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC
Features
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
Start-stop interface for absolute transducers and magnetostrictive sensors
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
Power supply 18 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Setup via operator software OS6.0
Serial RS232- / RS485 interface
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
Start-stop interface for absolute transducers and magnetostrictive sensors
USB interface and RS232/RS485 interface for configuration and serial readout
Page load link