• Features

    • High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
    • High level of internal safety (detection of internal errors and failures of the device components)
    • 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
    • 6 logical inputs for PNP signals [10 ... 30 VDC]
    • Input frequency up to 500 kHz
    • 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
    • 4 forced-guided redundant output relays with potential free change-over contact
    • Serial interface RS232 and RS485
    • Power supply 24 VAC and 17 ... 40 VDC
    • Compact norm panel housing
    • 6 digits LED display with 15 mm height
    • Display range -199999 ... 999999
    • Setup by keys or PC via serial RS232 Interface
    • Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface