Skip to content
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Maximum shaft speed 5000 rpm
Maximum shaft load
- radial: 10 N
Accuracy ± 7.5 arc. sec; ± 5.0 arc. sec
Starting torque at 20°C ≤ 0.01 Nm
Rotor moment of inertia < 20x10-6 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 0.7 kg
Operating temperature 0...+50°C
Storage temperature -30...+80°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: ≤ 30 N
- radial: ≤ 30 N
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 3.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000; 36000
Reference signal
- standard: 1 per shaft revolution
- distance coded for z = 18000: 36 per shaft revolution
- distance coded for z = 36000: 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.5 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.012 Nm
Rotor moment of inertia < 3.7x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.1 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Number of output pulses per revolution 3.600.000
Line number on disc (z) 36000
Reference signal
- 1 per shaft revolution
- 36 per shaft revolution
- 72 per shaft revolution
Permissible mech. speed ≤ 1000 rpm
Max. operating speed 300 to 500 rpm
Accuracy ± 2.0 arc. sec
Permissible shaft load - axial: 0.02 mm
- radial: 0.02 mm
Starting torque at 20°C ≤ 0.5 Nm
Rotor moment of inertia < 0.9x10-3 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 4.5 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Permissible shock (11 ms) ≤ 300m/s²
Features
Standard Size 36mm package (1.42")
Durable magnetic technology
Multiturn absolute encoder (12-bit/39-bit)
SSI and CANopen communications
Proven new turns counting technology — no gears or batteries
Features
Number of output pulses per revolution 18000-1800000 ppr
Line number on disc (z) 18000
Reference signal - standard: 1 per shaft revolution
- distance coded: 36 per shaft revolution
Permissible mech. speed ≤ 3000 rpm
Max. operating speed 600 to 1000 rpm
Accuracy grades ± 5.0 arc. sec
Permissible shaft runout - axial: 0.02 mm
- radial: ± 0.02 mm
Starting torque at 20°C ≤ 0.08 Nm
Rotor moment of inertia < 0.6x10-4 kgm2
Protection (IEC 529) IP64
Maximum weight without cable 1.2 kg
Operating temperature 0...+70°C
Storage temperature -30...+85°C
Maximum humidity (non-condensing) 98%
Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 3000 meters
Power supply 5 VDC (for LW213)
Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distances up to 3000 meters
Power supply 5 VDC (for LW214)
Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW215)
Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW216)
Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibers are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 Error input (LW217) resp. 1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 nsec.
Optical wavelength 850 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW217)
Power supply 10 ... 30 VDC (for LW217-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Pre-configured optical fibres are available
Features
1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
1 open-drain-output (LW218)
Maximum input frequency 1 MHz
Very short conversion time < 300 ns
Optical wavelength 1300 nm
Transmission distance up to 2000 meters
Power supply 5 VDC (for LW218)
Power supply 10 ... 30 VDC (for LW218-1)
Free adjustable SSI resolution from 1 ... 99 bit
Snap-on housing for top-hat rail (according to EN 60715)
Glass fibre cables are available ready-assembled
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
3 control inputs (hold) for PNP signals [10 ... 30 VDC]
Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
Input frequency up to 1 MHz
25-bit parallel output push-pull in BCD, binary or Gray code format
Power supply 18 ... 30 VDC
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
Start-stop interface for absolute transducers and magnetostrictive sensors
Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
Power supply 18 ... 30 VDC
Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
Simple parameterization via the OS6.0 user interface
Serial RS232 / RS485 interface
Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
USB interface and RS232/RS485 interface for configuration and serial readout
Features
Support brackets with a snap mechanism for easy installation of panel housings onto a 35 mm DIN rail (according to EN 60715)
Suitable for display units with front dimensions of 96 x 48 mm
Features
Support brackets with a snap mechanism for easy installation of panel housings onto a 35 mm DIN rail (according to EN 60715)
Suitable for display units with front dimensions of 96 x 96 mm
Features
Suitable for display units with front dimensions 96 x 48 mm
(fits not to Profibus indicator PB340)
Protection class IP65
Features
To increase the protection class in dusty or wet environments, several types of protection caps are available for motrona units.
Some of the elastic and transparent plastic caps allow you to operate the keypad or to set the thumbwheel switches behind the cap, without removing it.
Page load link