Skip to content
-
Features
- Absolute measuring method
- Hollow shaft diameter (up to 50 mm)
- Integrated stator coupling
- Simple installation
Typical field of application
- Rotational axes with reduced accuracy requirements
-
Features
- Absolute measuring method
- Large hollow shaft diameter (up to 100 mm)
- Integrated stator coupling
- Compact size for limited installation space
- System accuracy includes the deviation caused by the shaft connection
- Outstanding dynamic response
- Simple installation
Typical field of application
- Rotary tables
- Swivel heads
-
Features
- Incremental measuring method
- Solid shaft
- Separate shaft coupling for large mounting tolerances
- System accuracy does not include the deviation caused by the shaft connection
Typical field of application
-
Features
- Incremental measuring method
- Large hollow shaft diameter (up to 60 mm)
- Integrated stator coupling
- Compact size for limited installation space
- System accuracy includes the deviation caused by the shaft connection
- Outstanding dynamic response
- Simple installation
Typical field of application
- Rotary tables
- Swivel heads
-
Features
- Large hollow shaft diameter (up to 10 m with a scale tape)
- High shaft speeds up to 20,000 rpm
- No additional starting torque from shaft seals
- Segment versions
- Also available with Functional Safety Modular angle encoders with optical scanning are available with various graduation carriers:
-
- ERP/ERO: Glass circular scale with hub
- ERA/ECA 4000: Steel drum
- ERA 7000/8000: Steel scale tape
Typical field of application
- High-resolution rotary axes with high reproducibility
- Very high number of signal periods
- Small mounting space
- Small interpolation error and low signal noise
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- Preset range: 6 digits or 5 digits with sign
- DIL-switch for set up of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- DIL-switch for setup of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.12 ")
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- EtherCAT interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- EtherNET/IP interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen