Skip to content
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- 24 V auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-functional device for speed, position, timer, counter or velocity application
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Options can be combined.
-
Features
- 2 Incremental inputs with format A, /A, B, /B
- Differential, single-ended HTL / RS422
- Input frequency up to 1 MHz
- Power supply 18 ... 30 VDC
- 5 / 24 VDC auxiliary output for encoder supply
- 3.78 x 1.89-inch norm panel housing and IP65 protection
- Bright and high-contrast display with event-dependent color variations
- Emulation of a 7-segment display inclusively icons and units
- Intuitive and easy parameterization by plain text and touchscreen
- Multi-functional device for speed, process time, timer, counter or velocity application
- Operating modes such as scaling, average filter, start-up suppression
- Linearization with 24 control points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputsOptions can be combined.
-
Features
- 1 Strain gauge input
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
- Power supply 18 ... 30 VDC
- Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
- Simple parameterization via the OS6.0 user interface
- Serial RS232 / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- Pulse input in format A, B, 90° [HTL]
- Static Input for Set / Reset [HTL]
- Input frequency up to 20 kHz
- Power supply 24 VDC
- Standardised miniature switch panel housing
with the dimensions 48 x 24 x 59 mm
- 6 decades LED display with 8 mm digit height
- Display range -199999 ... 999999
- Counting frequency 15 ... 60 kHz, depending on the operating mode
- Programmable counting function (A with B as direction specification, sum A + B, difference A - B, position A / B with 90° phase offset)
- Switchable pulse multiplication (x2, x4) as well as adjustable multiplier and divider 0.0001 ... 99.9999
- Actual value memory (10 years)
- Simple parameterisation via 2 front keys and menu navigation