• Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
    • 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
    • SUB-D-9-pin male, galvanically isolated
  • Features

    • USB to RS232 converter (compatible with all existing Windows versions)
    • Serial RS232 cable (for connection between the converter and motrona unit)
    • One connector Sub-D-9 (male)
    • One connector Sub-D-9 (female)
    • Length 3 m (approx. 10 feet)
    • Windows driver CD enclosed
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Strain gauge input, 6-wire connection
    • Input pt100 and thermocouples (J and K)
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Adjustable bridge voltage 3 VDC to 10 VDC
    • 1 … 10 mV sensitivity
    • Standard installation housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols and units
    • Intuitive and simple parameterization through plain text and touchscreen
    • Numerous functions such as tare, filter, averaging
    • Linearization with 24 support points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    • Option IO: IO-Link Device V1.1
    Options can be combined.
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
    • 8-decade LCD display (colour: red, green, yellow)
    • Resistive touchscreen
    • Standard housing with 96 x 48 mm and IP65 protection
    • Intuitive and easy parameterization by plain text and touchscreen
    • Numerous functions such as scaling, filter, zero offset, counting direction etc.
    • Linearization with 24 interpolation points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Go to Top