Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- Preset range: 6 digits or 5 digits with sign
- DIL-switch for set up of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- DIL-switch for setup of the transmission parameters
- Dimension H x B x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.12 ")
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- Solder connection
- Metallised plastic enclosure
- Mounting screws included
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- EtherCAT interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- EtherNET/IP interface
- 3 control inputs for remote release
- Power supply 18 ... 30 VDC
- Norm panel housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols, units and bargraph
- Intuitive and simple parameterization through plain text and touchscreen
-
Features
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM300 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 4 potential-free changeover relay outputs
- 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
- Cutting length specification via keyboard or front BCD decade switch
- Power supply 24 VAC and 17 … 40 VDC
- Compact norm panel housing (according to EN 60715)
- Top hat rail mounting by using SM600 support brackets (option)
- Setup via keys or via PC by serial RS232 interface
- PROFIBUS connection via Motrona gateway PB251
-
Features
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available