Skip to content
-
Features
- Strain gauge input, 6-wire connection
- Input pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Power supply 18 ... 30 VDC
- Adjustable bridge voltage 3 VDC to 10 VDC
- 1 … 10 mV sensitivity
- Standard installation housing with 96 x 48 mm and protection class IP65
- Bright and high-contrast graphic display with event-dependent color variants
- Emulation of a 7-segment display with symbols and units
- Intuitive and simple parameterization through plain text and touchscreen
- Numerous functions such as tare, filter, averaging
- Linearization with 24 support points
Options
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
- Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
- Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
Options can be combined.
-
Features
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 1 SSI input (10 … 32 bit)
- for single-turn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
- Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- SSI clock frequency up to 1 MHz
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- 4 pulse inputs with format A, /A, B, /B [RS422]
- 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
- 8 control inputs for PNP signals [10 ... 30 VDC]
- 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
- Short loop time (depending on application)
- Power supply 18 ... 35 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via Windows operator software (free of charge)
- OnBoard interfaces: RS232 and CANopen
-
Features
- 20-bit parallel input with format BCD, binary or Gray-Code
- Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
- 4 status outputs, with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Power supply 10 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Serial RS232 / RS485 interface
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 … 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardised switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -199999 ... 999999 with 6 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- Scalable 14-bit analogue output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 4 preselector switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardised switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -199999 ... 999999 with 6 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 48 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 2 pre-selection switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 8 decades with 10 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 4 preselector switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 2 pre-selection switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- 2 scalable inputs in format A, /A, B, /B [HTL / TTL / RS422, 1-lane, 2-lane, balanced or unbalanced]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1MHz
- 4 fast transistor outputs, push-pull, short-circuit proof [5 ... 30 VDC]
- 4 output relays with potential-free changeover contact
- 4 programmable limits
- Power supply 24 VAC and 17 ... 40 VDC
- Standardized switch panel housing
- LED display 6 decades with 15 mm digit height
- Display range -19999999 ... 99999999 with 8 decades
- 4 preselector switches on the front
- Serial RS232 interface
- Dimensions W x H x D = 96 x 96 x 140 mm
-
Features
- Pulse input in format A, B, 90° [HTL]
- Static Input for Set / Reset [HTL]
- Input frequency up to 20 kHz
- Power supply 24 VDC
- Standardised miniature switch panel housing
with the dimensions 48 x 24 x 59 mm
- 6 decades LED display with 8 mm digit height
- Display range -199999 ... 999999
- Counting frequency 15 ... 60 kHz, depending on the operating mode
- Programmable counting function (A with B as direction specification, sum A + B, difference A - B, position A / B with 90° phase offset)
- Switchable pulse multiplication (x2, x4) as well as adjustable multiplier and divider 0.0001 ... 99.9999
- Actual value memory (10 years)
- Simple parameterisation via 2 front keys and menu navigation
Page load link