Skip to content
Features
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Display of alarm and error codes
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
Simple parameterization of motrona safety devices
Editing, saving and loading of parameters
Individual scalable process or speed indicator
Dual channel frequency indicator for visualization of the encoder frequency
Touch screen with intuitive menu guidance
1.54" OLED Display (128 x 64 Pixel)
Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
Features
MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
The number of successive axes can be extended arbitrarily via a cascading output.
MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
PROFIBUS connection possible via gateway PB251 (see accessories)
Features
6-wire connection for one strain gauge full bridge sensor
4 control inputs [HTL/PNP]
1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
6-wire connection for two independent strain gauge full bridge sensors
4 control inputs [HTL/PNP]
2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
4 control outputs for signalling different operation states
Power supply 18 ... 30 VDC
Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
Sensitivity of the sensor inputs 1 ... 10 mV
Transmission of the sensor data via RS485
Programming via USB and the user interface OS (freeware)
Protection class IP20
Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail
(according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
With signal splitter
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3/PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
2 pulse inputs with format A, /A, B, /B [RS422]
2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
Input frequency up to 500 kHz
Forced-guided redundant output relay (NO)
4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
Power supply 18 ... 30 V
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
Setup via USB port by operator software or plug-in display and programming unit BG230
Features
SIL3 and PLe certification
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
8 control inputs [HTL / PNP]
Input frequency up to 500 kHz
2 relay outputs 5... 250 VAC / VDC (NO)
4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Signal splitter
Power supply 18 ... 30 V
Wire monitoring of the sensor signals
Compact housing for 35 mm mounting top hat rail (according to EN 60715)
USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
BG200 operator panel for easy parameterization and display (optional)
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 500 kHz
2 output relays with potential-free change-over contact (forward, reward and zero motion)
2 transistor outputs with High-Side-Driver, short-circuit-proof
Power supply 17 ... 30 VDC
Snap-on housing for top hat rail (according to EN 60715)
DIL switch for setup of input characteristic and definition of standstill
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
14 Bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 fast transistor switching outputs [PNP]
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
14 bit analog output for ±10 V or 0/4 ... 20 mA
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
Input frequency up to 1 MHz
3 output relays
Power supply 17 ... 30 VDC
Auxiliary voltage output +5 V for the supply of TTL encoders
Snap-on housing for top hat rail (according to EN 60715)
LCD display, backlighted
Setup via keys or via PC by serial RS232 interface
Features
2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
2 control inputs for HTL / PNP signals [10 ... 30 VDC]
2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Features
1 Strain gauge input
3 VDC and 10 VDC bridge voltage per sensor connection
1 … 10 mV sensitivity
optionally 3 control inputs for PNP signals [10 ... 30 VDC]
IO link interface
Power supply 12 ... 30 VDC
Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
Features
Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse input in format A, B, Z [HTL]
Input frequency up to 1 MHz
Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
Pulse output in format A, B, Z [HTL]
Power supply 9 ... 30 VDC
Settings via DIL switches
Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
External HTL signals for various functions
Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
Snap-on housing for top-hat rail (acc. EN 60715)
Dimension (B x H X T) 22,5 x 102 x 102 mm
Features
High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
High level of internal safety (detection of internal errors and failures of the device components)
2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
6 logical inputs for PNP signals [10 ... 30 VDC]
Input frequency up to 500 kHz
4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
4 forced-guided redundant output relays with potential free change-over contact
Serial interface RS232 and RS485
Power supply 24 VAC and 17 ... 40 VDC
Compact norm panel housing
6 digits LED display with 15 mm height
Display range -199999 ... 999999
Setup by keys or PC via serial RS232 Interface
Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
Features
Pulse input with format A, B, Z [HTL] (10 ... 30 V)
Input frequency max. 200 kHz
Pulse output with format A, /A, B, /B, Z, /Z [RS422 / TTL]
Power supply 5 VDC
Converts HTL levels (A / B / Z) in TTL / RS422, incl. the inverted signals
Converts also static/separate directional information into a dual channel A / B signal with a 90° phase shift
Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
Features
Pulse input with format A, /A, B, /B, Z, /Z [TTL / RS422]
Input frequency max. 200 kHz
Pulse output with format A, B, Z [HTL]
Power supply 10 ... 30 VDC
Converts TTL / RS422 signals (A, /A, B, /B, Z, /Z) in HTL format with an output level of 10 ... 30 VDC
Generates additionally an A / B directional information with 90° phase shift‚ a static HIGH / LOW directional signal or separate directional pulses
Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
Features
1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
Input frequency up to 500 kHz
1 pulse output with format A, /A, B, /B, Z, /Z [RS422, HTL]
Power supply 5 ... 30 VDC
Potential separation between input and output
Possibility to convert A, B / 90 ° directional information into static directional signal and vice versa
Connections on the input as well as on the output either via sub-D plugs or plug-in screw terminals (parallel connections)
Snap-on housing for top-hat rail (according to EN 60715)
Features
Support brackets with a snap mechanism for easy installation of panel housings onto a 35 mm DIN rail (according to EN 60715)
Suitable for display units with front dimensions of 96 x 48 mm