Skip to content
-
Features
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Display of alarm and error codes
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- Simple parameterization of motrona safety devices
- Editing, saving and loading of parameters
- Individual scalable process or speed indicator
- Dual channel frequency indicator for visualization of the encoder frequency
- Touch screen with intuitive menu guidance
- 1.54" OLED Display (128 x 64 Pixel)
- Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x 0,59")
-
Features
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signalling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail
- (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
- With signal splitter
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3/PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
- Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
- Power supply 18 ... 30 V
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- Setup via USB port by operator software or plug-in display and programming unit BG230
-
Features
- SIL3 and PLe certification
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
- Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
- 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
- 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
- Safety related 14 bit analog output for 4 ... 20 mA (scalable)
- Signal splitter
- Power supply 18 ... 30 V
- Wire monitoring of the sensor signals
- Compact housing for 35 mm mounting top hat rail (according to EN 60715)
- USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
- BG200 operator panel for easy parameterization and display (optional)
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 500 kHz
- 2 output relays with potential-free change-over contact (forward, reward and zero motion)
- 2 transistor outputs with High-Side-Driver, short-circuit-proof
- Power supply 17 ... 30 VDC
- Snap-on housing for top hat rail (according to EN 60715)
- DIL switch for setup of input characteristic and definition of standstill
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- 14 Bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 fast transistor switching outputs [PNP]
- 14 bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 14 bit analog output for ±10 V or 0/4 ... 20 mA
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
- Input frequency up to 1 MHz
- 3 output relays
- Power supply 17 ... 30 VDC
- Auxiliary voltage output +5 V for the supply of TTL encoders
- Snap-on housing for top hat rail (according to EN 60715)
- LCD display, backlighted
- Setup via keys or via PC by serial RS232 interface
-
Features
- 1 Strain gauge input
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 3000 meters
- Power supply 5 VDC (for LW213)
- Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distances up to 3000 meters
- Power supply 5 VDC (for LW214)
- Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW215)
- Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
- 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW216)
- Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibers are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 nsec.
- Optical wavelength 850 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW217)
- Power supply 10 ... 30 VDC (for LW217-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Pre-configured optical fibres are available
-
Features
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
- Very short conversion time < 300 ns
- Optical wavelength 1300 nm
- Transmission distance up to 2000 meters
- Power supply 5 VDC (for LW218)
- Power supply 10 ... 30 VDC (for LW218-1)
- Free adjustable SSI resolution from 1 ... 99 bit
- Snap-on housing for top-hat rail (according to EN 60715)
- Glass fibre cables are available ready-assembled
-
Features
- High level of external safety (Recognition of electrical or mechanical errors in the machinery/sensor systems/wirings etc.)
- High level of internal safety (detection of internal errors and failures of the device components)
- 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- 6 logical inputs for PNP signals [10 ... 30 VDC]
- Input frequency up to 500 kHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 forced-guided redundant output relays with potential free change-over contact
- Serial interface RS232 and RS485
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
- Display range -199999 ... 999999
- Setup by keys or PC via serial RS232 Interface
- Dimension B x H x T = 110 x 48 x 140 mm (4,33 x 1,89 x 5,51")
-
Features
- Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Control input „Error Release“ for PNP signals [10 ... 30 VDC]
- Input frequency up to 400 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
- Output frequency up to 4 MHz [RS422]
- Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Adjustable multiplier for interpolation rates from 1:5 to 1:50
- Adjustable divider 1:1 – 1:255 to reduce the output frequency
Page load link